Sterling SSk-3 operating instructions Adjust the flap switch

Page 24

SSK-3

4.2.2. Adjust the flap switch

Remove the connecting plug “flap switch” from the connection housing of the hopper.

Connect an ohmmeter to PINS 2 and 3 of the connecting plug “flap switch”.

Release the nuts (A) of the flap switch (B) until the support can be displaced.

Open the outlet flap (C) so far that the front tip of the outlet flap is approx. 30 mm (1.18 inches) away from the sealing surface.

Displace the flap switch (B) until the contact of the magnet switch is closed.

Tighten the nuts (A) of the flap switch.

Check the adjustment:

In case of free hanging outlet flap (empty hopper loader) the contact of the magnet switch must be closed.

C

B

A

Outlet flap

If the outlet flap cannot be properly adjusted, replace the flap switch or the outlet flap with magnet.

Install the hopper.

&

Order numbers

 

flap switch with plug:

ID 29570

outlet flap with magnet:

ID 28647

 

 

SM3-610

Maintenance 23

Image 24
Contents SSK-3 Sterling Material ProcessingTechnical service Telephone 800 Edition 12/97SSK-3 Parts and Service Department Table of contents Safety instructions Safety instructionsSSK-3 Explanations and information For your safety For the safety of the equipmentInstallation instructions Transport Set-upSSK-3 Compressed-air supply only with compressed-air valves Electrical connection SSK-3 Functional description Functional descriptionMaintenance SSK-3 Maintenance intervals Disassembling the hopper SSK-3 Replace the sealing rings Nonreturn valve Outlet flap Adjust the flap switch Cleaning the hopper Spare parts list Spare parts listSSK-3 Technical data Dimension sheet