Hitachi series inverter manual Func Default Set Name / Description Value Code

Page 21

Func.

 

Default

Set

Name / Description

Value

Code

Value

 

–FE(F)/–FU

 

 

 

 

 

 

 

 

 

 

A003/

Base frequency setting

50.0

/ 60.0

 

A203

 

 

 

 

 

 

 

 

 

A004/

Maximum frequency setting

50.0

/ 60.0

 

A204

 

 

 

 

 

 

 

 

A005

[AT] selection

00

 

 

• 00 Select between [O] and [OI] at [AT]

 

 

 

 

• 01 [O]+[OI] ([AT] input is ignored)

 

 

 

 

• 02 Select between [O] and keypad pot

 

 

 

 

• 03 Select between [OI] and keypad pot

 

 

 

 

 

 

 

A011

Pot./O–L input active range start frequency

0.0

 

 

 

 

 

A012

Pot./O–L input active range end frequency

0.0

 

 

 

 

 

 

A013

Pot./O–L input active range start voltage

 

0.

 

 

 

 

 

A014

Pot./O–L input active range end voltage

100.

 

 

 

 

 

A015

Pot./O–L input start frequency enable

01

 

 

• 00 Use A011 starting value)

 

 

 

 

• 01 Use 0 Hz

 

 

 

 

 

 

 

 

A016

External frequency filter time constant

2.

/ 8.

 

 

 

 

 

 

A020/

Multi-speed frequency setting

 

0

 

A220

 

 

 

 

 

 

 

 

 

A021

Multi-speed frequency settings (for both motors)

0.0

/ 0.0

 

A022

 

0.0

/ 0.0

 

A023

 

0.0

/ 0.0

 

A024

 

0.0

/ 0.0

 

A025

 

0.0

/ 0.0

 

A026

 

0.0

/ 0.0

 

A027..

 

......

 

..A035

 

0.0

/ 0.0

 

 

 

 

 

A038

Jog frequency setting

1.00

 

 

 

 

 

A039

Jog stop mode

00

 

 

• 00 Free-run stop, jogging disabled during

 

 

 

 

motor run

 

 

 

 

• 01 Controlled deceleration, jogging disabled

 

 

 

 

during motor run

 

 

 

 

• 02 DC braking to stop, jogging disabled

 

 

 

 

during motor run

 

 

 

 

 

 

 

A041/

Torque boost select

00

 

A241

• 00 Manual torque boost

 

 

 

 

• 01 Automatic torque boost

 

 

 

 

 

 

 

A042/

Manual torque boost value

5.0(A042)/

 

A242

 

0.0 (A242)

 

 

 

 

 

A043/

Manual torque boost frequency adjustment

3.0/(A043)

 

A243

 

0.0(A243)

 

 

 

 

 

 

19

Image 21
Contents L2002 Series Inverter Quick Reference Guide Page UL Cautions, Warnings, and Instructions Wiring Warnings for Electrical Practices and Wire SizesAWG Terminal Tightening Torque and Wire SizeFuse and Circuit Breaker Sizes Wire ConnectorsMotor Overload Protection L3 U/T1 V/T2 W/T3 Power Circuit TerminalsDescription Ratings and Notes Control Circuit TerminalsAL2 L200 Basic Wiring DiagramHitachi Inverter Keypad OperationPage Keypad Navigation Map Program ModeStep Description Via Keypad Via Logic Terminals Powerup TestBasic Error Codes Error CodesE60 Error Trip ConditionsRestoring Factory Default Settings Group Monitoring Functions Parameter TablesTrip History and Inverter Status Monitor ModeGroup Standard Functions Group Main Profile ParametersFunc Default Set Name / Description Value Code Characteristic curve selection AVR voltage select Group Fine-tuning Functions Overload restriction operation mode Group Intelligent Terminal Functions C082 OI input span calibration Func Default Set Name / Description Group Expansion Card Functions Group Motor Constants FunctionsIntelligent Input Terminal Listing Symbol Code Input Terminal NameIntelligent Output Terminal Listing Analog Input ConfigurationOption Function Name Description Corresponding Code Analog Output Function Listing