Parameter tables for
•Some parameters have 2nd motor equivalents, indicated by the x2xx parameter codes in the
•Some parameters specify an option code. Where applicable, the options codes will be in a bulleted list in the Name/Description column.
•The default values apply to all models unless otherwise noted for each parameter...
•Some parameters cannot be edited during Run Mode, and certain Software Lock settings (B031) can prohibit all edits. If in doubt, place the inverter in Stop Mode or consult the inverter manual for details.
“F” Group: Main Profile Parameters
Func. |
| Name / Description | Default | Set |
Code |
| Value | Value | |
|
| |||
|
|
|
| |
|
|
|
| |
F001 | Output frequency setting | 0.0 |
| |
|
|
|
| |
F002 | Acceleration (1) time setting | 10.0 |
| |
|
|
|
| |
F202 | Acceleration (1) time setting, 2nd motor | 10.0 |
| |
|
|
|
| |
F003 | Deceleration (1) time setting | 10.0 |
| |
|
|
|
| |
F203 | Deceleration (1) time setting, 2nd motor | 10.0 |
| |
|
|
|
| |
F004 | Keypad Run key routing | 00 |
| |
| • 00 Forward | • 01 Reverse |
|
|
|
|
|
|
|
“A” Group: Standard Functions
Func. |
| Default | Set | |
Name / Description | Value | |||
Code | Value | |||
|
| |||
|
|
| ||
|
|
|
| |
|
|
|
| |
A001/ | Frequency source setting | 01 / 00 |
| |
A201 | • 00 Keypad potentiometer |
|
| |
| • 01 Control terminal |
|
| |
| • 02 Function F001 setting |
|
| |
| • 03 ModBus network input |
|
| |
| • 10 Calculate function input |
|
| |
|
|
|
| |
A002/ | Run command source setting | 01 / 02 |
| |
A202 | • 01 Input terminal FW or RV (assignable) |
|
| |
| • 02 Run key on keypad, or digital operator |
|
| |
| • 03 ModBus network input |
|
| |
|
|
|
|
18