Hitachi series inverter manual Motor Overload Protection

Page 6

400V Models

Motor output

Inverter Model

Ampere Rating for

 

 

kW

HP

 

Fuse or Breaker

 

 

 

 

 

 

 

 

 

 

0.4

1/2

–004HFE(F)2/HFU2

3

 

 

 

 

0.75

1

–007HFE(F)2/HFU2

6

 

 

 

 

1.5

2

–015HFE(F)2/HFU2

10

 

 

 

 

2.2

3

–022HFE(F)2/HFU2

10

 

 

 

 

3.0

4

–030HFE(F)2

15

 

 

 

 

4.0

5

–040HFE(F)2/HFU2

15

 

 

 

 

5.5

7 1/2

–055HFE(F)2/HFU2

20

 

 

 

 

7.5

10

–075HFE(F)2/HFU2

25

 

 

 

 

Motor Overload Protection

Hitachi L2002 inverters provide solid state motor overload protection, which depends on the proper setting of the following parameters:

B012 “electronic overload protection”

B212 “electronic overload protection, 2nd motor”

Set the rated current [Amperes] of the motor(s) with the above parame- ters. The setting range is 0.2 * rated current to 1.2 * rated current.

Warning: When two or more motors are connected to the inverter, they cannot be protected by the electronic overload pro- tection. Install an external thermal relay on each motor.

4

Image 6
Contents L2002 Series Inverter Quick Reference Guide Page Wiring Warnings for Electrical Practices and Wire Sizes UL Cautions, Warnings, and InstructionsTerminal Tightening Torque and Wire Size AWGWire Connectors Fuse and Circuit Breaker SizesMotor Overload Protection Power Circuit Terminals L3 U/T1 V/T2 W/T3Control Circuit Terminals Description Ratings and NotesAL2 Basic Wiring Diagram L200Inverter Keypad Operation HitachiPage Program Mode Keypad Navigation MapPowerup Test Step Description Via Keypad Via Logic TerminalsError Codes Basic Error CodesError Trip Conditions E60Restoring Factory Default Settings Parameter Tables Group Monitoring FunctionsMonitor Mode Trip History and Inverter StatusGroup Main Profile Parameters Group Standard FunctionsFunc Default Set Name / Description Value Code Characteristic curve selection AVR voltage select Group Fine-tuning Functions Overload restriction operation mode Group Intelligent Terminal Functions C082 OI input span calibration Func Default Set Name / Description Group Motor Constants Functions Group Expansion Card FunctionsSymbol Code Input Terminal Name Intelligent Input Terminal ListingAnalog Input Configuration Intelligent Output Terminal ListingAnalog Output Function Listing Option Function Name Description Corresponding Code