Hitachi NB5741XD manual Powerup Test, Step Description Via Keypad Via Logic Terminals

Page 9

Powerup Test

The Powerup Test procedure uses minimal parameter settings to run the motor. The procedure describes two alternative methods for commanding the inverter: via the inverter keypad, or via the logic terminals.

Check power input and motor output wiring (see page 4 diagram).

If using logic terminals for testing, verify correct wiring on [P24], [FW], [H], [O], and [L] (bottom row) per the diagram on page 4.

Reverse [RV] input wiring (defaults to terminal [2]) is optional.

Step

Description

Via Keypad

Via Logic

Terminals

 

 

 

 

 

 

 

 

 

 

 

1

Set speed command

A_01 = 00

A_01 = 01,

 

source setting

(keypad pot.)

[H–O–L] input

 

 

 

 

2

Set Run FW command

A_02 = 02

A_02 = 01,

 

source

(Run key)

[FW] input

 

 

 

 

3

Set Run REV command

C_02 = 01,

 

source

 

[RV] input

 

 

 

 

4

Set motor base freq.

A_03 = 60

 

 

 

5

Set keypad display to

Access D_01, press Func key, display

 

monitor freq.

will show 0.0

 

 

 

 

 

Perform safety check

Disconnect load from motor

 

 

 

 

6

 

Turn keypad pot.

Ensure voltage on

 

 

to MIN position

[O]—[L] termi-

 

 

 

nals= 0V

 

 

 

 

7

Run Forward command

Press Run key

Turn ON the

 

 

 

[FW] terminal

 

 

 

 

8

Increase speed

Rotate keypad

Increase voltage

 

 

pot. CW dir.

at [O]

 

 

 

 

9

Decrease speed

Rotate keypad

Decrease voltage

 

 

pot. CCW dir.

at [O]

 

 

 

 

10

Stop motor

Press Stop key

Turn OFF the

 

 

 

[FW] terminal

 

 

 

 

11

Run Reverse command

Turn ON the [RV]

 

(optional)

 

terminal

 

 

 

 

12

Stop motor

Turn OFF the

 

 

 

[RV] terminal

 

 

 

 

8

Image 9
Contents Hitachi Power Circuit Terminals Description Ratings and Notes Control Circuit TerminalsRUN L100 Basic Wiring DiagramHitachi Inverter Keypad OperationPage Keypad Navigation Map Step Description Via Keypad Via Logic Terminals Powerup TestError Codes Basic Error CodesError Name Probable Causes Code Step Display Error Trip ConditionsAction Display Function/Parameter Restoring Factory Default SettingsParameter Tables Group Monitoring FunctionsFunc Name / Description Units Code Trip History Navigation Map Monitor ModeGroup Main Profile Parameters Func Name / Description Default Set Code ValueGroup Standard Functions Default Func Name / Description Value Set Code FE / -FUAVR enabled AVR disabled AVR enabled except during decel Group Fine-tuning Functions B12 Level of electronic thermal setting Rated Current Group Intelligent Terminal Functions Rated Current Intelligent Input Terminal Listing Symbol Code Input Terminal NameExternal Frequency Command Input Analog Input ConfigurationIntelligent Output Terminal Listing Analog Output Function Listing