Hitachi NB5741XD manual Group Standard Functions

Page 16

“A” Group: Standard Functions

 

 

Default

 

Func.

Name / Description

Value

Set

Code

–FE / –FU /

Value

 

 

 

–FR

 

 

 

 

 

 

 

 

 

A_01

Frequency source setting

01 / 01 / 00

 

 

• 00 Keypad potentiometer

 

 

 

• 01 Control terminal

 

 

 

• 02 Function F_01 setting

 

 

 

 

 

 

A_02

Run command source setting

01 / 01 / 02

 

 

• 01 Input terminal FW or RV (assign-

 

 

 

able)

 

 

 

• 02 Run key on keypad, or digital

 

 

 

operator

 

 

 

 

 

 

A_03

Base frequency setting

50.0 / 60.0 /

 

 

 

60.0

 

 

 

 

 

A_04

Maximum frequency setting

50.0 / 60.0 /

 

 

 

60.0

 

 

 

 

 

A_11

O/OI–L input active range start

0.0

 

 

frequency

 

 

 

 

 

 

A_12

O/OI–L input active range end frequency

0.0

 

 

 

 

 

A_13

O/OI–L input active range start voltage

0

 

 

 

 

 

A_14

O/OI–L input active range end voltage

100

 

 

 

 

 

A_15

O/OI–L input start frequency enable

01

 

 

• 00 Use A_11 starting value)

 

 

 

• 01 Use 0 Hz

 

 

 

 

 

 

A_16

External frequency filter time constant

8

 

 

 

 

 

A_20

Multi-speed frequency setting

0

 

 

 

 

 

A_21

Multi-speed frequency settings

0 / 0 / 5

 

A_22

 

0 / 0 / 10

 

A_23

 

0 / 0 / 15

 

A_24

 

0 / 0 / 20

 

A_25

 

0 / 0 / 30

 

A_26

 

0 / 0 / 40

 

A_27

 

0 / 0 / 50

 

A_28

 

0 / 0 / 60

 

A_29..

 

0 / 0 / 0

 

..A_35

 

 

 

 

 

 

 

A_38

Jog frequency setting

1.0

 

 

 

 

 

A_39

Jog stop mode

00

 

 

• 00 Free-run stop, jogging disabled

 

 

 

during motor run

 

 

 

• 01 Controlled deceleration, jogging

 

 

 

disabled during motor run

 

 

 

• 02 DC braking to stop, jogging

 

 

 

disabled during motor run

 

 

 

 

 

 

15

Image 16
Contents Hitachi Power Circuit Terminals Control Circuit Terminals Description Ratings and NotesRUN Basic Wiring Diagram L100Inverter Keypad Operation HitachiPage Keypad Navigation Map Powerup Test Step Description Via Keypad Via Logic TerminalsBasic Error Codes Error CodesError Name Probable Causes Code Error Trip Conditions Step DisplayRestoring Factory Default Settings Action Display Function/ParameterGroup Monitoring Functions Parameter TablesFunc Name / Description Units Code Monitor Mode Trip History Navigation MapFunc Name / Description Default Set Code Value Group Main Profile ParametersDefault Func Name / Description Value Set Code FE / -FU Group Standard FunctionsAVR enabled AVR disabled AVR enabled except during decel Group Fine-tuning Functions B12 Level of electronic thermal setting Rated Current Group Intelligent Terminal Functions Rated Current Symbol Code Input Terminal Name Intelligent Input Terminal ListingAnalog Input Configuration External Frequency Command InputIntelligent Output Terminal Listing Analog Output Function Listing