Intelligent Output Terminal Listing
Symbol | Code | Input Terminal Name | |
|
|
|
|
|
|
|
|
RUN | 00 | Run signal |
|
|
|
|
|
FA1 | 01 | Freq. arrival type 1 | – constant speed |
|
|
|
|
FA2 | 02 | Freq. arrival type 2 | – |
|
|
| |
OL | 03 | Overload advance notice signal | |
|
|
| |
OD | 04 | Output deviation for PID control | |
|
|
|
|
AL | 05 | Alarm signal |
|
|
|
|
|
Analog Input Configuration
The following tables show the parameter settings required for vari- ous analog input signal types.
[AT] | External Frequency Command Input |
|
|
|
|
OFF | [O] — [L] |
|
|
ON | [OI] — [L] |
|
|
(not assigned to any input | Summation of [O] — [L] and [OI] — [L] |
terminal) |
|
|
|
Analog Output Function Listing
The following table shows all three functions available for assign- ment to the analog output terminal:
• Terminal [FM], option set by C_23
Option | Function | Description | Corresponding | |
Code | Name | Signal Range | ||
| ||||
|
|
|
| |
|
|
|
| |
00 | Output | Actual motor speed, | 0 to max. freq. in Hz | |
| frequency | represented by PWM |
| |
|
| signal |
| |
|
|
|
| |
01 | Output | Motor current (% of | 0 to 200% | |
| current | maximum rated output |
| |
|
| current), represented by |
| |
|
| PWM signal |
| |
|
|
|
| |
02 | Digital output | Output frequency | 0 to max. freq. in Hz | |
| frequency |
|
| |
|
|
|
|
22