Hitachi NB5741XD manual B12 Level of electronic thermal setting Rated Current

Page 19

 

 

 

 

Default

 

Func.

 

Name / Description

Value

Set

Code

 

–FE / –FU /

Value

 

 

 

 

 

 

 

–FR

 

 

 

 

 

 

 

 

 

B_12

Level of electronic thermal setting

Rated

 

 

 

 

 

current of

 

 

 

 

 

each inverter

 

 

 

 

 

B_13

Electronic thermal characteristic

01 / 01 / 00

 

 

• 00 Reduced torque

• 01 Const. torque

 

 

 

 

 

 

B_21

Overload restriction operation mode

01

 

 

• 00 Disabled

 

 

 

 

• 01 Enabled for accel and constant

 

 

 

speed

 

 

 

 

• 02 Enabled for constant speed only

 

 

 

 

 

 

B_22

Overload restriction setting

Rated

 

 

 

 

 

current

 

 

 

 

 

x 1.25

 

 

 

 

 

B_23

Deceleration rate at overload restriction

1.0

 

 

 

 

 

B_31

Software lock mode selection

01

 

 

• 00 Low-level access, [SFT] blocks

 

 

 

edits

 

 

 

 

• 01 Low-level access, [SFT] blocks

 

 

 

edits (except F_01 and Multi-speed

 

 

 

parameters)

 

 

 

 

• 02 No access to edits

 

 

 

• 03 No access to edits except F_01 and

 

 

 

Multi-speed parameters

 

 

 

 

 

 

B_32

Reactive current setting

58% rated

 

 

Note: For Japanese (–FR) versions, only

current

 

 

–055LFR, –055HFR, –075LFR, and

 

 

 

–075HFR models support this function.

 

 

 

 

 

 

B_81

[FM] terminal analog meter adjustment

80

 

 

 

 

 

B_82

Start frequency adjustment

0.5

 

 

 

 

 

B_83

Carrier frequency setting

5.0 / 5.0 /

 

 

 

 

 

12.0

 

 

 

 

 

B_84

Initialization mode (parameters or trip

00

 

 

history)

 

 

 

 

00 Trip history clear

 

 

 

 

01 Parameter initialization

 

 

 

 

 

 

B_85

Country code for initialization

01 / 02 / 00

 

 

• 00 Japan version

• 01 Europe

 

 

 

version

 

 

 

 

• 02 US version

 

 

 

 

 

 

 

B_86

Frequency scaling conversion factor

1.0

 

 

 

 

 

 

B_87

STOP key enable

 

00

 

 

• 00 Enable

• 01 Disable

 

 

 

 

 

 

 

 

18

Image 19
Contents Hitachi Power Circuit Terminals Description Ratings and Notes Control Circuit TerminalsRUN L100 Basic Wiring DiagramHitachi Inverter Keypad OperationPage Keypad Navigation Map Step Description Via Keypad Via Logic Terminals Powerup TestBasic Error Codes Error CodesError Name Probable Causes Code Step Display Error Trip ConditionsAction Display Function/Parameter Restoring Factory Default SettingsGroup Monitoring Functions Parameter TablesFunc Name / Description Units Code Trip History Navigation Map Monitor ModeGroup Main Profile Parameters Func Name / Description Default Set Code ValueGroup Standard Functions Default Func Name / Description Value Set Code FE / -FUAVR enabled AVR disabled AVR enabled except during decel Group Fine-tuning Functions B12 Level of electronic thermal setting Rated Current Group Intelligent Terminal Functions Rated Current Intelligent Input Terminal Listing Symbol Code Input Terminal NameAnalog Output Function Listing Analog Input ConfigurationExternal Frequency Command Input Intelligent Output Terminal Listing