Hitachi NB5741XD manual Restoring Factory Default Settings, Action Display Function/Parameter

Page 12

Restoring Factory Default Settings

 

 

Action

 

Display

Function/Parameter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

FUNC. , 1 or 2 as

 

b --

“B” Group selected

 

 

needed.

 

 

 

 

 

 

 

 

 

 

 

 

Press

FUNC. .

 

 

 

b 01

First “B” Group parame-

 

 

 

 

ter

 

 

 

 

 

 

 

 

 

 

 

 

 

Press/hold

1

until...

 

b 85

Country code for

 

 

initialization selected

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

FUNC. . If setting is

 

02

00 = Japan

 

01 = Europe

 

 

 

 

 

 

correct, then skip next step.

 

 

02 = United States

 

 

 

 

To change country code, press

1 or

2 to set; STR to store.

Press

FUNC. .

 

 

 

b 85

Country code for

 

 

 

 

initialization selected

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

2 .

 

 

 

b 84

Initialization function

 

 

 

 

selected

 

 

 

 

 

 

 

 

 

 

 

 

 

Press FUNC. .

 

 

 

00

0 = disable initialization,

 

 

 

clear trip history only

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

1 .

 

 

 

01

1 = enable initialization

 

 

 

 

 

 

 

 

 

 

 

 

 

Press

STR .

 

 

 

b 84

Initialization now

 

 

 

 

enabled to restore all

 

 

 

 

 

 

 

 

 

 

 

 

defaults

 

 

 

 

 

 

 

Press/hold

FUNC. ,

1 , and

b 84

First part of key sequence

 

2 . Do not release yet.

 

 

 

 

 

Press/hold RESETSTOP (STOP) for

d 00

Final part of special

sequence, “D_00” is

3 seconds, then release.

 

flashing

 

 

 

Now release the all keys

EU

Default parameter

together, only after “D_00”

USA

country code shown

display begins blinking.

during initialization

 

JP

 

 

 

 

Initialization is complete.

d 01

Function code for output

 

 

frequency monitor shown

11

Image 12
Contents Hitachi Power Circuit Terminals Control Circuit Terminals Description Ratings and NotesRUN Basic Wiring Diagram L100Inverter Keypad Operation HitachiPage Keypad Navigation Map Powerup Test Step Description Via Keypad Via Logic TerminalsError Codes Basic Error CodesError Name Probable Causes Code Error Trip Conditions Step DisplayRestoring Factory Default Settings Action Display Function/ParameterParameter Tables Group Monitoring FunctionsFunc Name / Description Units Code Monitor Mode Trip History Navigation MapFunc Name / Description Default Set Code Value Group Main Profile ParametersDefault Func Name / Description Value Set Code FE / -FU Group Standard FunctionsAVR enabled AVR disabled AVR enabled except during decel Group Fine-tuning Functions B12 Level of electronic thermal setting Rated Current Group Intelligent Terminal Functions Rated Current Symbol Code Input Terminal Name Intelligent Input Terminal ListingAnalog Input Configuration External Frequency Command InputIntelligent Output Terminal Listing Analog Output Function Listing