Graco 312497P important safety instructions Filling Master Divider Valve

Page 6

Setup

4.Continue to stroke the pump until the lubricant purges all the air out of the internal passages of the secondary divider valve and lubricant flows freely from all indicator ports with no evidence of included air.

5.Reinstall the port plugs or performance indicators in their respective positions in the secondary divider valve. Do not replace the port plugs or performance indicators in the master divider valve yet.

6.Repeat Steps 1-5 for each of the other lube lines between the master divider valve and all other sec- ondary divider valves.

NOTE: Do not replace any of the performance indica- tors or port plugs removed in Step 1 from the master divider valve assembly until the air-purging procedure described in Section 3 (Filling Master Divider Valve) has been completed.

Filling Master Divider Valve

Refer to FIG. 6. when performing this procedure.

LUBE POINT

SECONDARY

MASTER

BLEED

HERE

CYCLE PUMP

FIG. 6

TI11000

1.Verify that all port plugs or performance indicators have been removed from all indicator ports in the master divider valve.

2.Verify that the system pump is properly connected to the inlet port of the master divider valve.

3.Cycle the system pump sufficiently to fill the main feeder line between the pump and the master divider valve and the lubricant is observed being discharged from all of the indicator ports on the front of the master divider valve with no evidence of included air.

4.Reinstall the master divider valve port plugs or per- formance indicators into their respective positions.

6

312497P

Image 6
Contents Divider Type Maximum Pressure Lube PointsPressure kPSI SectionsEquipment Misuse Hazard Setup Pressure Relief ProcedureDivider Valves Component IdentificationTypical Divider Valve Combinations KeyPrefilling Lubricant Distributor Lines Filling Secondary-to-Lube Point LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Repair Section Air purging afterTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Lube Point Secondary Master Remove Indicator Or Port Plug Rupture Indicator Performance IndicatorsReset Indicator with Memory Automatic Relief Indicator4a. Master Divider Valve Equipped With Performance Indicator Assembly Torque ft-lbs N.m Torque Values *see ,Contamination Blockage Separation BlockageParts Technical Data DimensionsMD Series Part No. DescriptionTechnical Data MJ SeriesRef Part No. Description MSP Series Crossport Plate Optional Parts MSP Series 312497P MHH Series Lube Outlet Inlet Typical Parts MXP Series /04 Ti11477 #2/33/0/24 0,!4% /04 Ref Part No. Description MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 MX Series 312497P Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator Rupture-to-Atmosphere Indicator with Spud AssemblyCycle Indicators Rupture DiscsSingling and Crossporting Bar Assemblies Cycle Switches Cycle Counters Part NoPart Numbers Proximity Cycle Switches Description Type Part Number Pins SealProximity Switch Connection Cables Base Section Sub AssembliesConnection Cables for 312497P Graco Standard Warranty Graco Information