Graco 312497P 4a. Master Divider Valve Equipped With Performance Indicator

Page 14

Repair

4a. Master Divider Valve Equipped With Performance

Indicator

With manual pump connected to the master divider valve as outlined in Locating Blockages, Step 3, raise pressure to 2000 psi (14 MPa, 138 bar). The indicators in the indicator ports will signal the loca- tion of the blockage. An indicator in the up position indicates pressure is in that outgoing line and sig- nals the blockage is in the area being served from this outlet (FIG. 12).

If no indicator pins are protruding, the blockage is in the master divider valve.

HAND PUMP

NOTE:

If all indicator port plugs are removed, the master will not cycle. Blockage is in this divider valve.

When indicator port plug of a blocked area is removed, a small shot of trapped lubricant will usu- ally surge out of this outlet as the inlet pressure on the divider valve drops.

If testing (Step 4) indicates a blockage in the master divider valve, this divider valve must be disassem- bled and cleaned. See Clean Divider Valve, Step 7, page 15.

HAND PUMP

SYSTEM PUMP

INDICATOR PIN UP

LUBE OUTLETS

LUBE OUTLETS

INDICATOR PORT

MASTER

DIVDER

VALVE

SECONDARY

DIVIDER

VALVE

PLUGS

MASTERREMOVED DIVDER

VALVE

SECONDARY

DIVIDER

FIG. 12

TI11103

VALVE

TI11104

4b. Master Divider Valve Equipped Without Performance

Indicator

1)With manual pump connected to the master divider valve as outlined in Locating Blockages, Step 3, raise pressure to 2000 psi (14 MPA, 138 bar).

2)Remove, one at a time, each indicator port plug and attempt to operate manual pump after each plug is removed. Do not exceed 2000 psi (14 MPa, 138 bar)

3)If pressure drops and the master cycles freely after an indicator port plug is removed, then blockage is downstream in the area that is being served from that outlet. See Locating Blockages, Step 3.

FIG. 13

5.If in Step 4, a blockage has been indicated downstream of the master divider valve, install a manual pump in the indicator port of the master divider valve that is common to the blocked area. (See FIG. 13).

a.Proceed to downstream secondary divider valve and remove all indicator port plugs.

b.Slowly operate manual pump. If lubricant can be discharged freely through each of the indicator ports of this divider valve, the blockage is not in the supply line or the divider valve. Go to step 6.

If lubricant is not freely discharged through open indicator ports of the second divider valve, the blockage is in this divider valve or its supply line. Disconnect supply line at secondary inlet

14

312497P

Image 14
Contents Divider Type Maximum Pressure Lube PointsPressure kPSI SectionsEquipment Misuse Hazard Setup Pressure Relief ProcedureDivider Valves Component IdentificationTypical Divider Valve Combinations KeyFilling Master-to-Secondary Lube Lines Prefilling Lubricant Distributor LinesFilling Secondary-to-Lube Point Lines Filling Master Divider Valve Repair Section Air purging afterTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Lube Point Secondary Master Remove Indicator Or Port Plug Rupture Indicator Performance IndicatorsReset Indicator with Memory Automatic Relief Indicator4a. Master Divider Valve Equipped With Performance Indicator Assembly Torque ft-lbs N.m Torque Values *see ,Contamination Blockage Separation BlockageParts Technical Data DimensionsMD Series Part No. DescriptionTechnical Data MJ SeriesRef Part No. Description MSP Series Crossport Plate Optional Parts MSP Series 312497P MHH Series Lube Outlet Inlet Typical Parts MXP Series /04 Ti11477 #2/33/0/24 0,!4% /04 Ref Part No. Description MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 MX Series 312497P Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator Rupture-to-Atmosphere Indicator with Spud AssemblySingling and Crossporting Bar Assemblies Cycle IndicatorsRupture Discs Part Numbers Cycle SwitchesCycle Counters Part No Proximity Cycle Switches Description Type Part Number Pins SealConnection Cables for Proximity Switch Connection CablesBase Section Sub Assemblies 312497P Graco Standard Warranty Graco Information