Repair
fitting and slowly operate manual pump to verify location. If blockage is in this divider valve, go to step 7.
LUBE
OUTLET
SYSTEM PUMP
MASTER
DIVDER
VALVE
LUBE OUTLETS
INDICATOR PORT
PLUGS REMOVED
SECONDARY
DIVIDER
VALVE
HAND PUMP
BEARING
FIG. 14
6.Install manual pump into each indicator port of sec- ondary divider valve in turn and slowly operate pump (FIG. 14). If high pressure exists, blockage has been located. Look for crushed line, tight bearing, improperly drilled fittings and/or lube inlet port. Correct as necessary.
7.Clean Divider Valve
Table 4: Torque Values (*see FIG. 2, page 4)
NOTE: Dirt and foreign material will damage lubricating equipment. Perform all service and disassembly under the cleanest possible conditions.
a.Before disassembling any divider valve, make a sketch noting the arrangement of Valve Sec- tions. For example: INLET 10T - 20S - 10T - 30S - END (FIG. 15). Also remove end plugs only and try to move each piston back and forth without removing the piston from the valve sec- tion.
Inlet
10T
20S
10T
30S
End
FIG. 15
NOTICE
Do not insert hard metal objects into piston bore (i.e., punches, screwdrivers, etc.). Hard metal objects can damage the surface and cause divider valves to leak fluid. Use a brass rod and hand pressure only.
b.If all pistons move freely and there is no indica- tion of a more serious problem, replace end plugs.
c.Using a new gasket, tighten and torque as indi- cated in Table 4 (below).
|
|
| Assembly Torque |
|
| ||
| MJ | MD | MSP/MH | MX | MXP | MGO |
|
Tie Rod Nuts | 12 (16.3) | - | 23 (31.2) | 12 (16.3) | |||
|
|
|
|
|
|
|
|
Indicator Plugs* | 15 (20.3) | 18 (24.4) | |||||
|
|
|
| ||||
End Plugs* | - | 46 (62.4) | 15 (20.34) | ||||
|
|
|
|
| |||
Valve Section | - | - | - | - | |||
Mounting Screw |
|
|
|
| |||
|
|
|
|
|
|
|
|
312497P | 15 |