Graco 312497P important safety instructions Torque Values *see, Assembly Torque ft-lbs N.m

Page 15

Repair

fitting and slowly operate manual pump to verify location. If blockage is in this divider valve, go to step 7.

LUBE

OUTLET

SYSTEM PUMP

MASTER

DIVDER

VALVE

LUBE OUTLETS

INDICATOR PORT

PLUGS REMOVED

SECONDARY

DIVIDER

VALVE

HAND PUMP

BEARING

FIG. 14

6.Install manual pump into each indicator port of sec- ondary divider valve in turn and slowly operate pump (FIG. 14). If high pressure exists, blockage has been located. Look for crushed line, tight bearing, improperly drilled fittings and/or lube inlet port. Correct as necessary.

7.Clean Divider Valve

Table 4: Torque Values (*see FIG. 2, page 4)

NOTE: Dirt and foreign material will damage lubricating equipment. Perform all service and disassembly under the cleanest possible conditions.

a.Before disassembling any divider valve, make a sketch noting the arrangement of Valve Sec- tions. For example: INLET 10T - 20S - 10T - 30S - END (FIG. 15). Also remove end plugs only and try to move each piston back and forth without removing the piston from the valve sec- tion.

Inlet

10T

20S

10T

30S

End

FIG. 15

NOTICE

Do not insert hard metal objects into piston bore (i.e., punches, screwdrivers, etc.). Hard metal objects can damage the surface and cause divider valves to leak fluid. Use a brass rod and hand pressure only.

b.If all pistons move freely and there is no indica- tion of a more serious problem, replace end plugs.

c.Using a new gasket, tighten and torque as indi- cated in Table 4 (below).

 

 

 

Assembly Torque ft-lbs (N.m)

 

 

 

MJ

MD

MSP/MH

MX

MXP

MGO

MSD-SST

Tie Rod Nuts

12 (16.3)

-

5-8 (6.8-10.9)

23 (31.2)

6-9 (8.1-12.2)

12 (16.3)

5-8 (6.8-10.9)

 

 

 

 

 

 

 

 

Indicator Plugs*

6-7

15 (20.3)

8-9

18 (24.4)

12-15

6-8

5-7 (6.8-9.5)

 

(8.1-9.5)

 

(10.9-12.2)

 

(16.3-20.3)

(8.1-10.9)

 

End Plugs*

11-13

-

12-15

46 (62.4)

46-50

15 (20.34)

6-8 (8.1-10.9)

 

(14.9-17.6)

 

(16.3-20.3)

 

(62.4-67.8)

 

 

Valve Section

-

-

8-9

-

12-13

-

8-9

Mounting Screw

 

 

(10.9-12.2)

 

(16.3-17.6)

 

(10.9-12.2)

 

 

 

 

 

 

 

 

312497P

15

Image 15
Contents Sections Maximum Pressure Lube PointsPressure kPSI Divider TypeEquipment Misuse Hazard Pressure Relief Procedure SetupKey Component IdentificationTypical Divider Valve Combinations Divider ValvesPrefilling Lubricant Distributor Lines Filling Secondary-to-Lube Point LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Lube Point Secondary Master Remove Indicator Or Port Plug Automatic Relief Indicator Performance IndicatorsReset Indicator with Memory Rupture Indicator4a. Master Divider Valve Equipped With Performance Indicator Torque Values *see , Assembly Torque ft-lbs N.mSeparation Blockage Contamination BlockagePart No. Description Technical Data DimensionsMD Series PartsMJ Series Technical DataRef Part No. Description MSP Series Crossport Plate Optional Parts MSP Series 312497P MHH Series Lube Outlet Inlet Typical Parts MXP Series /04 Ti11477 #2/33/0/24 0,!4% /04 Ref Part No. Description MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 MX Series 312497P Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere IndicatorCycle Indicators Rupture DiscsSingling and Crossporting Bar Assemblies Cycle Switches Cycle Counters Part NoPart Numbers Description Type Part Number Pins Seal Proximity Cycle SwitchesProximity Switch Connection Cables Base Section Sub AssembliesConnection Cables for 312497P Graco Information Graco Standard Warranty