Graco 312497P important safety instructions Lube Point Secondary Master Disconnect Hand Pump

Page 11

Repair

Section 4: Purging Air After Adding or Replacing a Master Divider Valve Module

 

LUBE POINT

 

 

SECONDARY

 

 

MASTER

DISCONNECT

HAND PUMP

BLEED

 

LINE

HERE

 

 

 

NEW VALVE

 

 

 

BLOCK

 

 

 

TI11116

FIG. 10

Steps 1-7, refer to FIG. 10.

1.Install the new or replacement module into the mas- ter divider valve assembly. Also connect the tubing or hoses to the appropriate secondary divider valve(s) or lubrication point(s) if the new/replace- ment module is a base section.

2.Do not completely tighten the connection(s) at the secondary divider valve’s inlet or at lubrication points.

3.Disconnect and remove the line from the pump at the inlet of the master divider valve.

4.Attach a hand pump filled with clean, filtered lubri- cant to the inlet port on the master divider valve.

5.Operate the hand pump until air-free lubricant is observed flowing from each secondary valve’s lube inlet connector and/or each lubrication point’s con- nector.

6.Tighten the fitting at the secondary valve inlet or at the lubrication port while lubricant is still flowing.

7.Remove the hand pump and reconnect the system pump to the inlet of the master divider valve.

The system is now ready for operation.

312497P

11

Image 11
Contents Sections Maximum Pressure Lube PointsPressure kPSI Divider TypeEquipment Misuse Hazard Pressure Relief Procedure SetupKey Component IdentificationTypical Divider Valve Combinations Divider ValvesFilling Master-to-Secondary Lube Lines Prefilling Lubricant Distributor LinesFilling Secondary-to-Lube Point Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Lube Point Secondary Master Remove Indicator Or Port Plug Automatic Relief Indicator Performance IndicatorsReset Indicator with Memory Rupture Indicator4a. Master Divider Valve Equipped With Performance Indicator Torque Values *see , Assembly Torque ft-lbs N.mSeparation Blockage Contamination BlockagePart No. Description Technical Data DimensionsMD Series PartsMJ Series Technical DataRef Part No. Description MSP Series Crossport Plate Optional Parts MSP Series 312497P MHH Series Lube Outlet Inlet Typical Parts MXP Series /04 Ti11477 #2/33/0/24 0,!4% /04 Ref Part No. Description MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 MX Series 312497P Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere IndicatorSingling and Crossporting Bar Assemblies Cycle IndicatorsRupture Discs Part Numbers Cycle SwitchesCycle Counters Part No Description Type Part Number Pins Seal Proximity Cycle SwitchesConnection Cables for Proximity Switch Connection CablesBase Section Sub Assemblies 312497P Graco Information Graco Standard Warranty