Graco 312497P important safety instructions Setup, Pressure Relief Procedure

Page 3

Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever you see this symbol.

This equipment stays pressurized until pressure is manually relieved. To help prevent serious injury from pressurized fluid, such as skin injection, splashing fluid and moving parts, follow the Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing the equipment.

1.Verify pump feeding valve is stopped and discon- nected from, or locked out of it’s driver.

2.Using a wrench, slowly loosen inlet nut.

3.Then, using a wrench, slowly loosen each port nut.

Setup

The divider valve is shipped ready to install in your sys- tem. It has been factory-tested and should not require any additional modification.

For MJ and MX series valves only: Gaskets (a) must be installed between every valve section (b) of the block assembly to prevent leaking.

b

a

b

FIG. 1

Setup

NOTICE

Do not install a divider valve into a system rated for more than the valve’s maximum operating pressure. This type of installation could result in o-ring damage and cause the divider valve to leak.

To install the divider valve in your system:

1.Determine an appropriate, remote mounting loca- tion.

2.Install a rupture to atmosphere fitting with a blow-out disk that is rated for 7,500 psi (52 MPa, 517 bar) or less between the force feed lubricator pump and master divider valve inlet.

3.Install an analog pressure gauge at the inlet to the divider valve.

4.Install a slow or no cycle shutdown in one of the pis- ton enclosure plugs. Program it to shut down after no more than 180 seconds without a complete cycle.

5.Torque. See Table 4 on page 15.

As long as lubricant is supplied under pressure to the inlet section of the divider assembly, valves sections will continue to operate in a progressive manner. Divider assemblies always follow a constant discharge pattern. Whenever lubricant flow ceases, the valving pistons will stop. When flow resumes, it will start again at the same point in the discharge cycle.

312497P

3

Image 3
Contents Sections Maximum Pressure Lube PointsPressure kPSI Divider TypeEquipment Misuse Hazard Pressure Relief Procedure SetupKey Component IdentificationTypical Divider Valve Combinations Divider ValvesPrefilling Lubricant Distributor Lines Filling Secondary-to-Lube Point LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Lube Point Secondary Master Remove Indicator Or Port Plug Automatic Relief Indicator Performance IndicatorsReset Indicator with Memory Rupture Indicator4a. Master Divider Valve Equipped With Performance Indicator Torque Values *see , Assembly Torque ft-lbs N.mSeparation Blockage Contamination BlockagePart No. Description Technical Data DimensionsMD Series PartsMJ Series Technical DataRef Part No. Description MSP Series Crossport Plate Optional Parts MSP Series 312497P MHH Series Lube Outlet Inlet Typical Parts MXP Series /04 Ti11477 #2/33/0/24 0,!4% /04 Ref Part No. Description MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 MX Series 312497P Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere IndicatorCycle Indicators Rupture DiscsSingling and Crossporting Bar Assemblies Cycle Switches Cycle Counters Part NoPart Numbers Description Type Part Number Pins Seal Proximity Cycle SwitchesProximity Switch Connection Cables Base Section Sub AssembliesConnection Cables for 312497P Graco Information Graco Standard Warranty