Multiquip GB4000 manual Maintenance, Replacing Lamp, Caution

Page 26

MAINTENANCE

REPLACING LAMP

DANGER

Never attempt to replace lamp in a wet place. The possibility exists of electric shock.

WARNING

Always allow sufficient time for the lamp to cool down before replacing.The possibility exists of severe burns if hot lamp is touched.

\ CAUTION

Always shutdown power source and remove balloon assembly from mast when replacing a broken lamp. Utmost care should be taken in handling broken lamp. The possibility exists of serious injury from handling a broken lamp.

1.Unzip the zipper at the bottom of the balloon and roll the balloon up to expose the lamp. See Figure 15.

BALLOON

ZIPPER

Figure 15. Exposing Balloon

2.Release the lamp guard hooks from the poles and remove the two lamp guards. See Figure 16.

LAMP

GUARD

LOCK HOOK

Figure 16. Removing Lamp Guard

3.Press the tabs on the lamp holder and push up lamp holder to release it from lamp. Do the same to the lower lamp if necessary. See Figure 17.

LAMP HOLDER

Figure 17. Lamp Holder

4.Remove lamp from the lamp socket by turning lamp counterclockwise. See Figure 18.

LAMP

LAMP

SOCKET

Figure 18. Removing Lamp

5.Install new lamp into socket and turn lamp in a clockwise direction until tight. See Figure 19.

LAMP

LAMP

SOCKET

Figure 19. Installing New Lamp

PAGE 26 —GB4000 BALLOON LIGHT• OPERATION AND PARTS MANUAL — REV. #1 (02/25/14)

Image 26
Contents Model GB4000 This Manual Must Accompany the Equipment AT ALL TimesPage Page Table of Contents GB4000 Balloon LightParts Ordering Procedures Ordering parts has never been easierSafety Symbols Safety InformationSafety Messages General Safety Light Tower Safety Lamp SafetyEngine Safety Any enclosed or narrow areaFuel Safety Towing Safety Light TowerTransporting Safety  Never lift the equipment while engine is runningElectrical Safety  Never operate GB4000 in winds in excess of 40 MPH 64 km/hBattery Safety Environmental SafetySpecifications SpecificationsDimensions Closed OpenedFootcandle Plot Footcandle PlotGeneral Information Components GB4000 ComponentsPreparation SetupPower Disconnection Remove the adapter plate kit hardware from its container Lock Washer HEX NUT Lamp Mounting Balloon Power CableJunction BOX Mounting Lamp Cable Connections GB4000Inflating Balloon and Turning on Lamps LT12 only OperationRemoving Balloon Protective Cover Inflating Balloon and Turning on Lamps MLT only Deflating and Storing Balloon\ Caution MaintenanceReplacing Lamp Replacing Balloon Unzipping BalloonSymptom Possible Problem Solution Location of Maintenance PartsWiring Diagram Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts GB4000 Balloon Light 1 to 3 unitsNameplate and Decals 120V 60Hz 4000 WPart Name QTY. Remarks Decal WARNING, Burn Hazard FrenchElectrical Assy Part Name QTY Remarks PlateElectrical Assy Part Name Bracket and J-BOX Assy BOX Relay Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help