Graco 334014A Fluid Supply Line, Fluid Outlet Line, Fluid Inlet and Outlet Ports

Page 11

Fluid Supply Line

See Typical Floor Mount Installation, page 12

1.Use grounded flexible, fluid supply hoses (G). See Grounding, page 8 .

2.If the inlet fluid pressure to the pump is more than 25% of the outlet working pressure, the ball check valves will not close fast enough, resulting in inefficient pump operation.

3.Excessive inlet fluid pressure also will shorten diaphragm life. Approximately 3 - 5 psi (0.02- 0.03 MPa, 0.21-0.34 bar) should be adequate for most materials.

4.For maximum suction lift (wet and dry), see Technical Data, page 20. For best results, always install the pump as close as possible to the material source.

Installation

Fluid Outlet Line

See Typical Floor Mount Installation, page 12.

1.Use grounded, flexible fluid hoses (L). See Grounding, page 8 .

2.Install a fluid drain valve (J) near the fluid outlet.

3.Install a shutoff valve (K) in the fluid outlet line.

Fluid Inlet and Outlet Ports

NOTE: Remove and reverse the manifold(s) to change the orientation of inlet or outlet port(s). Follow Torque Instructions, page 16.

1050HP — Aluminum Manifolds

The fluid inlet and outlet manifolds each have two 1 in. npt(f) or bspt threaded ports (M, N). Close off the unused port using the supplied plugs.

1050HP — Stainless Steel Manifolds

The fluid inlet and outlet manifolds each have one 1 in. npt(f) or bspt port.

334014A

11

Image 11
Contents Repair/Parts manual. Save these instructions Important Safety InstructionsRelated Manuals ContentsTo Specify the Configuration of a New Pump To Order Replacement PartsOrdering Information To Find Your Nearest DistributorConfiguration Number Matrix Pressurized Equipment Hazard Fire and Explosion HazardThermal Expansion Hazard Plastic Parts Cleaning Solvent HazardEquipment Misuse Hazard Personal Protective Equipment Toxic Fluid or Fumes HazardBurn Hazard Grounding InstallationTighten Fasteners Before Setup MountingAir Line See Typical Floor Mount Installation,KEY Air Exhaust Ventilation1050HP Aluminum Manifolds Fluid Supply LineFluid Outlet Line Fluid Inlet and Outlet PortsTypical floor mount installation Typical Floor Mount InstallationHigh/Low Lever Pressure Relief ProcedureOperation Flush the Pump Before First UsePump Shutdown Start and Adjust the PumpTighten Threaded Connections MaintenanceMaintenance Schedule LubricationTorque Instructions Aluminum and SST Dimensions and MountingAluminum SSTAir Consumption Performance ChartsLow Pressure Setting Fluid Pressure How to Read the ChartsHigh Pressure Setting Technical Data Non-wetted external parts Fluid Temperature RangeFluid Temperature Range Wetted partsGraco Information Graco Standard Husky Pump Warranty