Graco 334014A important safety instructions Equipment Misuse Hazard, Thermal Expansion Hazard

Page 6

Warnings

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated

system component. See Technical Data in all equipment manuals.

• Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer.

Do not leave the work area while equipment is energized or under pressure.

Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only.

Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards.

Make sure all equipment is rated and approved for the environment in which you are using it.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

THERMAL EXPANSION HAZARD

Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury.

• Open a valve to relieve the fluid expansion during heating.

• Replace hoses proactively at regular intervals based on your operating conditions.

PLASTIC PARTS CLEANING SOLVENT HAZARD

Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage.

• Use only compatible water-based solvents to clean plastic structural or pressure-containing parts.

• See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s MSDSs and recommendations.

6

334014A

Image 6
Contents Important Safety Instructions Repair/Parts manual. Save these instructionsContents Related ManualsTo Find Your Nearest Distributor To Order Replacement PartsOrdering Information To Specify the Configuration of a New PumpConfiguration Number Matrix Fire and Explosion Hazard Pressurized Equipment HazardPlastic Parts Cleaning Solvent Hazard Equipment Misuse HazardThermal Expansion Hazard Toxic Fluid or Fumes Hazard Burn HazardPersonal Protective Equipment Mounting InstallationTighten Fasteners Before Setup GroundingSee Typical Floor Mount Installation, Air LineAir Exhaust Ventilation KEYFluid Inlet and Outlet Ports Fluid Supply LineFluid Outlet Line 1050HP Aluminum ManifoldsTypical Floor Mount Installation Typical floor mount installationFlush the Pump Before First Use Pressure Relief ProcedureOperation High/Low LeverStart and Adjust the Pump Pump ShutdownLubrication MaintenanceMaintenance Schedule Tighten Threaded ConnectionsTorque Instructions SST Dimensions and MountingAluminum Aluminum and SSTHow to Read the Charts Performance ChartsLow Pressure Setting Fluid Pressure Air ConsumptionHigh Pressure Setting Technical Data Wetted parts Fluid Temperature RangeFluid Temperature Range Non-wetted external partsGraco Standard Husky Pump Warranty Graco Information