Installation

Installation

The Typical Floor Mount Installation, page 12, is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.

Tighten Fasteners Before Setup

Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 16. After the first day of operation, retorque the fasteners.

Mounting

The pump exhaust air may contain contaminants. Ventilate to a remote area. See Air Exhaust Ventilation, page 10.

Never move or lift a pump under pressure. If dropped, the fluid section may rupture. Always follow the Pressure Relief Procedure, page 13, before moving or lifting the pump.

1.Be sure the mounting surface can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.

2.For all mountings, be sure the pump is bolted directly to the mounting surface. Mount the pump horizontally, with the feet at the bottom of the pump. Do not mount the pump on a vertical surface, such as a wall.

3.For ease of operation and service, mount the pump so air valve, air inlet, fluid inlet and fluid outlet ports are easily accessible.

Grounding

The equipment must be grounded to reduce the risk of static sparking. Static sparking can cause fumes to ignite or explode. Grounding provides an escape wire for the electric current.

Pump: Loosen the grounding screw (GS). Insert one end of a 12 ga. minimum ground wire (R) behind the grounding screw and tighten the screw securely. Connect the clamp end of the ground wire to a true earth ground. A ground wire and clamp, Part 238909, is available from Graco.

Figure 1 Grounding Screws and Wires

8

334014A

Image 8
Contents Important Safety Instructions Repair/Parts manual. Save these instructionsContents Related ManualsTo Order Replacement Parts Ordering InformationTo Find Your Nearest Distributor To Specify the Configuration of a New PumpConfiguration Number Matrix Fire and Explosion Hazard Pressurized Equipment HazardThermal Expansion Hazard Plastic Parts Cleaning Solvent HazardEquipment Misuse Hazard Personal Protective Equipment Toxic Fluid or Fumes HazardBurn Hazard Installation Tighten Fasteners Before SetupMounting GroundingSee Typical Floor Mount Installation, Air LineAir Exhaust Ventilation KEYFluid Supply Line Fluid Outlet LineFluid Inlet and Outlet Ports 1050HP Aluminum ManifoldsTypical Floor Mount Installation Typical floor mount installationPressure Relief Procedure OperationFlush the Pump Before First Use High/Low LeverStart and Adjust the Pump Pump ShutdownMaintenance Maintenance ScheduleLubrication Tighten Threaded ConnectionsTorque Instructions Dimensions and Mounting AluminumSST Aluminum and SSTPerformance Charts Low Pressure Setting Fluid PressureHow to Read the Charts Air ConsumptionHigh Pressure Setting Technical Data Fluid Temperature Range Fluid Temperature RangeWetted parts Non-wetted external partsGraco Standard Husky Pump Warranty Graco Information