Technical Data

Technical Data

 

US

 

 

 

Metric

Maximum fluid working pressure

200 psi

 

 

 

1.4 MPa,14.0 bar

Air pressure operating range

20-100 psi

 

 

0.14-0.69 MPa, 1.4-6.9 bar

Fluid displacement per cycle

 

 

 

 

 

Low Pressure Setting

0.17 g

 

 

 

0.64 l

High Pressure Setting

0.20 g

 

 

 

0.76 l

Air consumption

at 70 psi, 20 gpm

 

 

 

at 4.8 bar, 76 lpm

Low Pressure Setting

26 scfm

 

 

0.7 cubic meters per minute

High Pressure Setting

51 scfm

 

 

1.4 cubic meters per minute

Maximum values with water as media under submerged inlet conditions at ambient temperature:

Maximum air consumption

 

 

 

 

 

Low Pressure Setting

59 scfm

 

 

1.7 cubic meters per minute

High Pressure Setting

95 scfm

 

 

2.7 cubic meters per minute

Maximum free-flow delivery

 

 

 

 

 

Low Pressure Setting

50 gpm

 

 

 

189 lpm

High Pressure Setting

46 gpm

 

 

 

174 lpm

Maximum pump speed

 

 

 

 

 

Low Pressure Setting

 

280 cpm

 

High Pressure Setting

 

225 cpm

 

Maximum suction lift (varies widely

16 ft dry,

 

 

 

4.9 m dry

based on ball/seat selection and

29 ft wet

 

 

 

8.8 m wet

wear, operating speed, material

 

 

 

 

 

properties, and other variables)

 

 

 

 

 

Maximum size pumpable solids

1/8 in

 

 

 

3.2 mm

Recommended cycle rate for continuous

 

93–140

cpm

 

use

(in Low or High pressure setting)

Recommended cycle rate for circulation

 

20

cpm

 

systems

(in Low or High pressure setting)

Air inlet size

 

3/4

npt(f)

 

Fluid inlet size

1 in.

npt(f) or 1 in.

bspt

Fluid outlet size

1 in.

npt(f) or 1 in.

bspt

Weight

48 lb (aluminum manifolds)

 

21.8 kg (aluminum manifolds)

 

60 lb (SST manifolds)

 

27.2 kg (SST manifolds)

20

334014A

Image 20
Contents Important Safety Instructions Repair/Parts manual. Save these instructionsContents Related ManualsTo Order Replacement Parts Ordering InformationTo Find Your Nearest Distributor To Specify the Configuration of a New PumpConfiguration Number Matrix Fire and Explosion Hazard Pressurized Equipment HazardThermal Expansion Hazard Plastic Parts Cleaning Solvent HazardEquipment Misuse Hazard Personal Protective Equipment Toxic Fluid or Fumes HazardBurn Hazard Installation Tighten Fasteners Before SetupMounting GroundingSee Typical Floor Mount Installation, Air LineAir Exhaust Ventilation KEYFluid Supply Line Fluid Outlet LineFluid Inlet and Outlet Ports 1050HP Aluminum ManifoldsTypical Floor Mount Installation Typical floor mount installationPressure Relief Procedure OperationFlush the Pump Before First Use High/Low LeverStart and Adjust the Pump Pump ShutdownMaintenance Maintenance ScheduleLubrication Tighten Threaded ConnectionsTorque Instructions Dimensions and Mounting Aluminum SST Aluminum and SSTPerformance Charts Low Pressure Setting Fluid PressureHow to Read the Charts Air ConsumptionHigh Pressure Setting Technical Data Fluid Temperature Range Fluid Temperature RangeWetted parts Non-wetted external partsGraco Standard Husky Pump Warranty Graco Information