Baldor BSC 7107 DC manual Section Specifications and Data, Dimensions

Page 16

Section 4

Specifications and Data

Specifications

Input Voltage

. . . . . . .

. . . . . 120 VAC±10%

Output Voltage (Filtered Output)

. . . . . 0 to 140 VDC

Load Current (Continuous) . . . .

. . . . . . . . . 7 Amperes

Overload Current

. . . . . . .

150% for 30 seconds

Speed Range

. . . . . . .

. . . . . . . . . . . . . . 50:1

Max Speed Trimpot . . .

. . . 70 to 100% of Input VAC

Min Speed Trimpot . . . .

Adjustable 0–30% OF MAX.

Current Limit Trimpot . .

. . . . . . .

. . . . . . . . . Adjustable

Acceleration

. . . . . . .

. . . . Fixed, Fast Start

Motor Hall Spacing (Electrical)

Selectable 60° or 120°

Closed Loop Speed Regulation ± 1/2% Of Base Speed

Speed Control

. . . . . . .

. . . . . . . 5KPot or

 

0 - 6.2 VDC Isolated Signal

Operating Temperature

. . . . . 32° - 113°F ( 0° - 45°C )

Dimensions

Width

6.75 in. (172 mm)

Length

9.00 in. (228 mm)

Depth

2.90 in. (74 mm)

Weight

41 oz. (1.17 Kg)

Specifications 4-1

Image 16
Contents BSC DC Brushless Control Installation and Operating Manual MN1231Table of Contents Ii Table of Contents Section General Information IntroductionLimited Warranty Safety Notice PrecautionsBe sure the system is properly grounded before Section Receiving & Installation InstallationControl Installation ReceivingAC Power Connection Refer to Figure Speed Potentiometer Refer to FigureControl Connection Locations Sensor and Motor Connections Refer to Figure Connect the three motor leads to P1 terminals as followsReverse Operation 1st Time Power Up Procedure or after a motor is replaced Section Adjustments Current Limit AdjustmentMinimum Speed Adjustment Adjusting Closed Loop GainSpecifications Section Specifications and DataDimensions Hall Signal Timing Diagram Box Fort Smith, AR 479 Fax 479