Reverse Operation

Terminal P4–REV is the forward/reverse control. You can reverse motor direction by connecting P4–REV to P4–COM. Use a jumper wire, switch, relay, or an open collector NPN transistor.

Caution: Before reversing directions, make sure the motor is stopped. This control is not designed for plug reversing.

Sometimes it may be necessary to reverse motor direction without using terminal P4–REV. This is done by stopping the motor and exchanging terminals P1–Φ1 with P1–Φ2 on the lower board, and terminals P4–S1 with P4–S3 on the upper board.

Receiving & Installation 2-5

Image 12
Contents BSC DC Brushless Control Installation and Operating Manual MN1231Table of Contents Ii Table of Contents Section General Information IntroductionLimited Warranty Safety Notice PrecautionsBe sure the system is properly grounded before Section Receiving & Installation InstallationControl Installation ReceivingAC Power Connection Refer to Figure Speed Potentiometer Refer to FigureControl Connection Locations Sensor and Motor Connections Refer to Figure Connect the three motor leads to P1 terminals as followsReverse Operation 1st Time Power Up Procedure or after a motor is replaced Section Adjustments Current Limit AdjustmentMinimum Speed Adjustment Adjusting Closed Loop GainSection Specifications and Data SpecificationsDimensions Hall Signal Timing Diagram Box Fort Smith, AR 479 Fax 479