Furuno B042-004, B042-016, B042-008 manual Scroll bar, Dialog box for 200 kHz

Page 30

3. INITIAL SETTINGS

3.Press [!] to select [HIGH] CONNECTION or [LOW] CONNECTION (whichever is installed), and then press [+] or [-] to show the dialog box. Select CONNECTED for the connection of transducer.

4.Press ["] or [!] to close the dialog box.

5.Press [!] to select FREQ.

6.Press [+] or [-] to show the dialog box. The scroll bar at the bottom of the dialog box shows cursor position in relation to the entire menu.

41 kHz 45 kHz 50 kHz 67 kHz 68 kHz 88 kHz 107 kHz 150kHz

Scroll bar

7.Press [+] or [-] to select frequency, (HIGH: 41 kHz and higher, LOW: 28 kHz and higher are available.) and then press ["] or [!] to close the dialog box.

8.Press [!] to select TRANSDUCER, and then press [+] or [-] to open the dialog box.

200B-5S (1kW) 50/200-1ST (1kW) 50/200-1T (1 kW) 200B-8/8B (2 kW)

Dialog box for 200 kHz

9.Press [+] or [-] to select model number, and then press ["] or [!] to close the dialog box.

10.Jot down alphabet which appears on “TAP” line. You may change the terminal board setting at the rear of the display unit depending on the transducer type which is connected. For details, see page 3-5.

11.Follow steps 3-10 to enter model number of other transducer if installed.

Note: For dual-frequency transducer, enter both high and low frequencies and set the same transducer model number for both high and low frequencies.

12.Press [!] to select PWR REDUCTION, and then press [+] or [-] to open the dialog box.

OFF ON

13.Press [+] or [-] to turn the power reduction ON or OFF (default setting).

14.Press ["] or [!] to close the dialog box.

15.Confirm settings and turn off the power.

Note: If the system detects frequency mismatch the message “Frequency unmatch error! Press any key to go to Transducer setting menu.” appears at the next powering of the equipment. Press any key to go to the transducer setting menu and reenter transducer data.

3-4

Image 30
Contents Color LCD Sounder 00080922000 Safety Instructions Damage to the transducer may result Table of Contents System Configuration Equipment Lists Standard supplyOptions Available transducers Vii Viii KW/2 kW transducer 28/45 Steel 28F-8 Steel 50B-6/6B Xii Xiii Xiv Mounting Display UnitMounting considerations Mounting procedure Removing the display unit from the mounting baseFlush mounting Flush mounting display unitWater Temperature Sensor option How to mount transom mount water Temperature sensor T-02MTBTransducer Thru-hull mount water temperature sensor T-02MSB, T-03MSB Water temperature/speed sensor ST-02MSB, ST-02PSB Wiring Wiring diagram for standard-type FCV-1100LTransducer Wiring Standard EquipmentPower cable GroundWiring Optional Equipment Input/Output SentencesThis page is intentionally left blank Initial Setting Language SettingInitial display screen Transducer Data Maker Frequency Type RemarksInstallation main menu Entering transducer data by transducer model numberScroll bar Dialog box for 200 kHzTransducer setting Display unit, rear viewTerminal board Entering transducer data by transducer specifications Menu for manual entry of transducer specificationsWater Temperature Sensor Setting Temp Setting menuSensor Nav Data, Heading Sensor Setting NAV Data Setting menuTrue MAG Installation menu Propagation VelocityDemonstration Mode Demo menuRestoring Default Settings This page is intentionally left blank Appendix Transducer 50BL-12/50BL-24H AP-1Appendix NEW BLT Transducers AP-2AP-3 Appendix 2 NEW BLT TransducersAP-4 Page Page Page Page Nov Page