Furuno B042-004, B042-016, B042-008 manual Water Temperature Sensor Setting, Temp Setting menu

Page 33

3. INITIAL SETTINGS

d)Use [+] or [-] to set the value for the frequency which is connected, and then press [!] or ["] to close the dialog box. (Available range: HIGH; 40 – 220 kHz, LOW; 25 – 220 kHz)

e)To operate the transducer in reduced power (for example, when vessel is in dry dock), press ["] to select PWR REDUCTION, and then press [+] or [-] to open the dialog box.

OFF ON

f)Press [+] or [-] to turn the power reduction ON, and then press [!] or ["] to close the dialog box.

6.Confirm settings and turn off the power.

3.3Water Temperature Sensor Setting

If a water temperature sensor is connected, set up as follows:

1.Turn on the power and turn the [FUNCTION] switch to the MENU position.

2.Press [!] and [+] to select SYSTEM at the top of the screen.

3.Press ["] to select TEMP SETTING, and then press [+] to open that menu.

DISP ALM TX/RX E/S SYSTEM

TEMP SETTING

TEMP UNIT

 

:

˚F

 

TEMP INPUT

: SENSOR

TEMP ADJUST

: +0.00˚F (-20 +20)

TEMP OUTPUT

: OFF

TEMP READOUT

: OFF

TEMP GRAPH

: OFF

TEMP COLOR

: STD

Select temperature unit.

[-/+]: Change set, [EXIT]: Exit

TEMP SETTING menu

4. The cursor is selecting TEMP UNIT; press [+] or [-] to open the dialog box.

CF

5.Press [+] or [-] to select the temperature unit, and then press [!] or ["] to close the dialog box.

3-7

Image 33
Contents Color LCD Sounder 00080922000 Safety Instructions Damage to the transducer may result Table of Contents System Configuration Equipment Lists Standard supplyOptions Available transducers Vii Viii KW/2 kW transducer 28/45 Steel 28F-8 Steel 50B-6/6B Xii Xiii Xiv Mounting Display UnitMounting considerations Removing the display unit from the mounting base Mounting procedureFlush mounting display unit Flush mountingWater Temperature Sensor option How to mount transom mount water Temperature sensor T-02MTBTransducer Thru-hull mount water temperature sensor T-02MSB, T-03MSB Water temperature/speed sensor ST-02MSB, ST-02PSB Wiring diagram for standard-type FCV-1100L WiringPower cable Wiring Standard EquipmentTransducer GroundInput/Output Sentences Wiring Optional EquipmentThis page is intentionally left blank Initial Setting Language SettingInitial display screen Maker Frequency Type Remarks Transducer DataEntering transducer data by transducer model number Installation main menuDialog box for 200 kHz Scroll barTransducer setting Display unit, rear viewTerminal board Menu for manual entry of transducer specifications Entering transducer data by transducer specificationsTemp Setting menu Water Temperature Sensor SettingSensor NAV Data Setting menu Nav Data, Heading Sensor SettingTrue MAG Propagation Velocity Installation menuDemo menu Demonstration ModeRestoring Default Settings This page is intentionally left blank AP-1 Appendix Transducer 50BL-12/50BL-24HAP-2 Appendix NEW BLT TransducersAppendix 2 NEW BLT Transducers AP-3AP-4 Page Page Page Page Nov Page