Graco 312497G important safety instructions Bleed Hose Here Lube Point Secondary Master

Page 12

Repair

Section 5: Purging Air After Adding or Replacing a Secondary Divider Valve Module

BLEED HOSE

HERE

LUBE POINT

SECONDARY

MASTER

BLEED

HERE

NEW VALVE

BLOCK

REMOVE INDICATOR

OR PORT PLUG

HAND PUMP

TI11115

FIG. 10

Steps 1-8, refer to FIG. 10.

1.Install the new or replacement module to the sec- ondary divider valve assembly. Also connect the tubing or hoses to the appropriate lubrication point if the new/replacement module is a base section.

2.Do not completely tighten the connection(s) at the lubrication point.

3.Remove the performance indicator or indicator port plug from the working valve section on the second- ary divider valve assembly corresponding to the out- let port and line connected to a particular lube point.

4.Attach a hand pump filled with clean, filtered lubri- cant to the port on the secondary divider valve that was opened in Step 3.

5.Operate the hand pump until air-free lubricant is observed flowing from the loosened connector at the lube point.

6.Tighten the fitting at the lube point while lubricant is still flowing.

7.Repeat Steps 3 - 6 for any additional lubrication points connected to the new module.

8.Remove the hand pump and reinstall the perfor- mance indicator or port plug removed in Step 3 into the secondary divider valve’s open port.

The system is now ready for operation.

12

312497G

Image 12
Contents Maximum Pressure Lube Points Pressure kPSIDivider Type SectionsPressure Relief Procedure Setup Component IdentificationTypical Divider Valve Combinations Divider ValvesPrefilling Lubricant Distributor Lines Filling Secondary-to-Lube Point LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Repair Section Air purging afterTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Performance Indicators Reset Indicator with MemoryRupture Indicator Automatic Relief Indicator4a. Master Divider Valve Equipped With Performance Indicator Torque Values *see , Assembly Torque ft-lbs MSP/MH MXP MGOContamination Blockage Separation BlockageTechnical Data DimensionsMD Series PartsMJ Series Lbs oz 1.55 kgParts MSP Series Crossport Plate Optional Parts MSP Series 312497G MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator Rupture-to-Atmosphere Indicator with Spud AssemblyCycle Indicators Rupture DiscsSingling and Crossporting Bar Assemblies 1175Cycle Switches Cycle Counters Part NoPart Numbers Proximity Cycle Switches Description Type Part Number Pins SealProximity Switch Connection Cables Connection Cables forGraco Standard Warranty Graco Information