Repair

Repair

General Repair Instructions

Purging Air From the System

Before performing any repair procedures, relieve pressure, page 2.

Pressure test distribution blocks yearly or every 8000 hours. Replace seals and divider valves as necessary.

Before machine operation is resumed following mainte- nance or repair, manual system air purging must be per- formed.

There are several air purging procedures available depending upon the maintenance or repair procedure.

NOTE: Use only clean oil filtered to the SAE -recom- mended cleanliness level of ISO 18/14 (ISO Standard 4406) when prefilling a system. The manufacturers of the machine tool and its component bearings should be consulted to ensure that the ISO 18/14 cleanliness level is adequate.

Page

Section

Air purging after:

 

 

 

8

1

Replacing line between a secondary divider valve and lube point.

 

 

 

9

2

Replacing a line between the master divider valve and a secondary

 

 

divider valve.

 

 

 

10

3

Replacing a line between pump and master divider valve.

 

 

 

11

4

Adding or replacing any component in a master divider valve assembly.

 

 

 

12

5

Adding or replacing any component in module in a secondary divider

 

 

valve assembly.

 

 

 

312497G

7

Image 7
Contents Sections Maximum Pressure Lube PointsPressure kPSI Divider TypePressure Relief Procedure Divider Valves SetupComponent Identification Typical Divider Valve CombinationsFilling Secondary-to-Lube Point Lines Prefilling Lubricant Distributor LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Automatic Relief Indicator Performance IndicatorsReset Indicator with Memory Rupture Indicator4a. Master Divider Valve Equipped With Performance Indicator MSP/MH MXP MGO Torque Values *see , Assembly Torque ft-lbsSeparation Blockage Contamination BlockageParts Technical DataDimensions MD SeriesLbs oz 1.55 kg MJ SeriesParts MSP Series Crossport Plate Optional Parts MSP Series 312497G MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere Indicator1175 Cycle IndicatorsRupture Discs Singling and Crossporting Bar AssembliesCycle Counters Part No Cycle SwitchesPart Numbers Description Type Part Number Pins Seal Proximity Cycle SwitchesConnection Cables for Proximity Switch Connection CablesGraco Information Graco Standard Warranty