Graco 312497G important safety instructions TI11113

Page 9

Repair

Section 2: Purging Air from Master to Secondary Divider Valve Lube Lines

LUBE POINT

SECONDARY

MASTER

REMOVE INDICATOR

OR PORT PLUG

BLEED HERE FIRST

 

AFTER BLEEDING INLET,

 

HAND PUMP

REMOVE ALL INDICATORS

 

 

OR PORT PLUGS AND BLEED

TI11113

 

ALL PORTS

FIG. 7

Steps 1- 9, refer to FIG. 7.

1.Install the lines from the master divider valve to the secondary divider valve, but do not completely tighten the connection at the secondary divider valve’s inlet.

2.Remove the performance indicator port plug or the performance indicator from the working valve sec- tion on the master divider valve assembly corre- sponding to the outlet port and the line connected to the secondary valve.

3.Attach a hand pump filled with clean, filtered lubri- cant on the master divider valve that was opened in Step 2.

4.Operate the hand pump until air-free lubricant is observed flowing freely from the secondary valve’s lube inlet connector.

5.Tighten the fitting at the secondary valve’s inlet while lubricant is still flowing.

6.Remove all of the indicators or indicator port plugs from the secondary divider valve’s working sections.

7.Operate the hand pump again until air-free lubricant is observed flowing out of all the secondary divider valve’s indicator ports.

8.Reinstall all of the performance indicators or port plugs in the secondary divider valve while lubricant is still flowing from the ports.

9.Remove the hand pump and reinstall the perfor- mance indicator or indicator plug removed in Step 2 into the master divider working valve’s open port.

The system is now ready for operation.

312497G

9

Image 9
Contents Pressure kPSI Maximum Pressure Lube PointsDivider Type SectionsPressure Relief Procedure Component Identification SetupTypical Divider Valve Combinations Divider ValvesFilling Secondary-to-Lube Point Lines Prefilling Lubricant Distributor LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Reset Indicator with Memory Performance IndicatorsRupture Indicator Automatic Relief Indicator4a. Master Divider Valve Equipped With Performance Indicator MSP/MH MXP MGO Torque Values *see , Assembly Torque ft-lbsSeparation Blockage Contamination BlockageDimensions Technical DataMD Series PartsLbs oz 1.55 kg MJ SeriesParts MSP Series Crossport Plate Optional Parts MSP Series 312497G MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere IndicatorRupture Discs Cycle IndicatorsSingling and Crossporting Bar Assemblies 1175Cycle Switches Cycle Counters Part NoPart Numbers Description Type Part Number Pins Seal Proximity Cycle SwitchesConnection Cables for Proximity Switch Connection CablesGraco Information Graco Standard Warranty