Repair

fitting and slowly operate manual pump to verify location. If blockage is in this divider valve, go to step 7.

LUBE

OUTLET

SYSTEM PUMP

MASTER

DIVDER

VALVE

LUBE OUTLETS

INDICATOR PORT

PLUGS REMOVED

SECONDARY

DIVIDER

VALVE

HAND PUMP

BEARING

FIG. 13

6.Install manual pump into each indicator port of sec- ondary divider valve in turn and slowly operate pump (FIG. 13). If high pressure exists, blockage has been located. Look for crushed line, tight bearing, improperly drilled fittings and/or lube inlet port. Correct as necessary.

7.Clean Divider Valve

NOTE: Dirt and foreign material will damage lubricating equipment. Perform all service and disassembly under the cleanest possible conditions.

a.Before disassembling any divider valve, make a sketch noting the arrangement of Valve Sec- tions. For example: INLET 10T - 20S - 10T - 30S - END (FIG. 14). Also remove end plugs only and try to move each piston back and forth without removing the piston from the valve sec- tion.

Inlet

10T

20S

10T

30S

End

FIG. 14

NOTICE

Do not insert hard metal objects into piston bore (i.e., punches, screwdrivers, etc.). Hard metal objects can damage the surface and cause divider valves to leak fluid. Use a brass rod and hand pressure only.

b.If all pistons move freely and there is no indica- tion of a more serious problem, replace end plugs.

c.Using a new gasket, tighten and torque as indi- cated in Table 1 (page 11).

Table 4: Torque Values (*see FIG. 1, page 3)

 

 

 

Assembly Torque (ft-lbs)

 

 

 

 

 

 

 

 

 

 

 

 

MJ

MD

 

MSP/MH

MX

 

MXP

MGO

 

 

 

 

 

 

 

 

 

Tie Rod Nuts

12

 

 

5-8

23

 

6-9

12

 

 

 

 

 

 

 

 

 

Indicator Plugs*

6-7

15

 

8-9

18

 

12-15

6-8

 

 

 

 

 

 

 

 

 

End Plugs*

11-13

 

 

12-15

46

 

46-50

15

 

 

 

 

 

 

 

 

 

Valve Section

-

-

 

8-9

-

 

12-13

-

Mounting Screw

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

312497G

15

Image 15
Contents Sections Maximum Pressure Lube PointsPressure kPSI Divider TypePressure Relief Procedure Divider Valves SetupComponent Identification Typical Divider Valve CombinationsFilling Secondary-to-Lube Point Lines Prefilling Lubricant Distributor LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Automatic Relief Indicator Performance IndicatorsReset Indicator with Memory Rupture Indicator4a. Master Divider Valve Equipped With Performance Indicator MSP/MH MXP MGO Torque Values *see , Assembly Torque ft-lbsSeparation Blockage Contamination BlockageParts Technical DataDimensions MD SeriesLbs oz 1.55 kg MJ SeriesParts MSP Series Crossport Plate Optional Parts MSP Series 312497G MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere Indicator1175 Cycle IndicatorsRupture Discs Singling and Crossporting Bar AssembliesCycle Switches Cycle Counters Part NoPart Numbers Description Type Part Number Pins Seal Proximity Cycle SwitchesConnection Cables for Proximity Switch Connection CablesGraco Information Graco Standard Warranty