Repair

Locating and Repairing

Blockages

Blocks will cause a higher than normal pumping pres- sure. Depending on the application or system design, this blockage will usually result in a complete loss of lubricant flow into the total system and no bearing will be receiving lubrication.

The loss of flow due to a blockage is first indicated with the higher than normal system pressure that is devel- oped by the pump as it attempts to overcome this block- age. Higher pressure is limited, isolated and signaled through the use of various performance indicators, reset and relief, incorporated into the system design.

Performance Indicators

Performance indicators are pressure-sensitive devices that pinpoint excessive pressure in the lubricating sys- tem.

These devices are installed in the indicator ports of divider valves, signal a fault either by causing an indica- tor pin to protrude or by releasing lubricant into the atmosphere.

NOTE: Never block a lube outlet that is designed to dis- charge lubricant.

Reset Indicator with Memory

Reset indicators stop lube system operation when a fault occurs. These devices can be used in either master or secondary divider valves.

When a lube line becomes blocked, the resultant high pressure pushes the indicator pin through the opening in the cap. The high pressure prevents the affected divider valve piston from completing its cycle, causing a pres- sure backup through the divider valve which trips a pres- sure switch upstream from the valve and shuts off the pump.

The indicator pin remains extended until it is reset man- ually. This helps locate the lube line that is blocked.

Rupture Indicator

Rupture indicators are used on MSP/MH divider valve applications where lube system pressure exceed 2500 psi. The high pressure from the lube line blockage causes a disc to rupture. The lubricant then forces an indicator to protrude, locating the blockage. The high pressure backs up through the system and trips a switch to shut the system off. When the fault is corrected, the disc must be replaced and the pin reset manually.

Automatic Relief Indicator

An automatic relief indicator pinpoints lube line blockage but allows the lube system to continue supplying lubri- cant to points that are not blocked. They are used pri- marily in secondary divider valves. The excessive pressure created by line blockage moves a piston, enabling the lubricant to escape through a vent. When the pressure is relieved, the spring resets the piston. Because these devices permit the lube system to keep operating when a lube point is blocked, a separate pres- sure switch connected to an audible alarm should be used to warn of high pressure.

Locating and Repairing Blockages

1.Make a visual inspection of the system. Check for crushed lines or improper divider valve installation.

2.Verify that each divider valve outlet required to dis- charge lubricant can do so and that no pipe plugs have been installed in an outlet designed to serve a bearing or another divider valve.

3.Use a manual pump with a gauge. Fill the pump with clean, filtered lubricant. Connect the manual pump to the inlet of the master divider valve and slowly operate pump. If system will not cycle freely, below 1500 psi, see Master Divider Valve Equipped with Performance Indicator [Step 4a (below)].

NOTE: Use only clean oil filtered to the SAE -recom- mended cleanliness level of ISO 18/14 (ISO Standard 4406) when prefilling a system. The manufacturers of the machine tool and its component bearings should be consulted to ensure that the ISO 18/14 cleanliness level is adequate.

312497G

13

Image 13
Contents Pressure kPSI Maximum Pressure Lube PointsDivider Type SectionsPressure Relief Procedure Component Identification SetupTypical Divider Valve Combinations Divider ValvesFilling Secondary-to-Lube Point Lines Prefilling Lubricant Distributor LinesFilling Master-to-Secondary Lube Lines Filling Master Divider Valve Section Air purging after RepairTI11098 TI11113 Purging Air from Pump to Master Divider Valve Lines Lube Point Secondary Master Disconnect Hand Pump Bleed Hose Here Lube Point Secondary Master Reset Indicator with Memory Performance IndicatorsRupture Indicator Automatic Relief Indicator4a. Master Divider Valve Equipped With Performance Indicator MSP/MH MXP MGO Torque Values *see , Assembly Torque ft-lbsSeparation Blockage Contamination BlockageDimensions Technical DataMD Series PartsLbs oz 1.55 kg MJ SeriesParts MSP Series Crossport Plate Optional Parts MSP Series 312497G MHH Series Lube Outlet Inlet Typical Part No. Description MXP Series Ti11477 Parts MGO Series 54,%43 $#!4/2 0/243 Parts MX Series v /54,%4 Parts MX Series Accessories Rupture Indicator MH Divider Valves Only Rupture-to-Atmosphere Indicator with Spud Assembly Rupture-to-Atmosphere IndicatorRupture Discs Cycle IndicatorsSingling and Crossporting Bar Assemblies 1175Cycle Counters Part No Cycle SwitchesPart Numbers Description Type Part Number Pins Seal Proximity Cycle SwitchesConnection Cables for Proximity Switch Connection CablesGraco Information Graco Standard Warranty