Yamaha M2500, Yamaha Mixing Consol owner manual Mute groups, Direct recall

Page 41

The Scene Memory function

Mute groups

By setting the Utility mode item oP (recall operation)

to “,” you can use the on/off settings of scene memory numbers 1–8 as “mute groups.” In this case, the DIRECT RECALL 1–8 switches will function as “mute group switches” that control mute groups.

The differences in operation between the “

(direct recall) and “” (mute group) settings of the oP (recall operation) item are explained below.

Direct recall

If you press the DIRECT RECALL 1 switch to recall scene memory 1, and then press the DIRECT RECALL 3 switch to recall scene memory number 3, the on/off settings of scene memory number 1 will be cancelled, and replaced by the on/off settings of scene memory number 3.

Scene memory number 1

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

MUTE

ON

ON

MUTE

ON

(OFF)

 

 

(OFF)

 

Scene memory number 3

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON

ON

ON

MUTE

MUTE

 

 

 

(OFF)

(OFF)

In the case of Direct Recall

1

2

3On/off settings of memory number 1 are recalled

4

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

 

5

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

 

6

OFF

ON

ON

OFF

ON

7

8

1

2

3Switch to the on/off settings of memory number 3

4

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

 

5

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

 

6

OFF

ON

ON

OFF

OFF

7

 

 

 

 

 

8

 

 

 

 

 

Mute group

If you press the DIRECT RECALL 1 switch to recall scene memory number 1, and then press the DIRECT RECALL 3 switch to recall scene memory number 3, the mute (off) settings of scene memory number 1 will remain, and only the mute settings of scene memory number 3 will be added. (At this time, both DIRECT RECALL switches 1 and 3 will be on.) If you then press the DIRECT RECALL 1 switch once again, the mute settings of scene memory number 3 will remain, and the mute settings of scene memory num- ber 1 will be cancelled.

Mute group 1 (scene memory number 1)

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

MUTE

ON

ON

MUTE

ON

(OFF)

 

 

(OFF)

 

Mute group 3 (scene memory number 3)

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON

ON

ON

MUTE

MUTE

 

 

 

(OFF)

(OFF)

In the case of Mute Group

1

2

3The mute settings of memory number 1 are recalled

4

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

 

5

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

 

6

MUTE

ON

ON

MUTE

ON

7

8

1

2

3The mute settings of memory number 3 are added

4

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

 

5

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

 

6

MUTE

ON

ON

MUTE

MUTE

7

 

 

 

 

 

8

 

 

 

 

 

1

2

3The mute settings of memory number 1 are cancelled

4

CHECK

CHECK

CHECK

CHECK

CHECK

ON

ON

ON

ON

ON

 

5

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

ON/EDIT

 

6

ON

ON

ON

MUTE

MUTE

7

 

 

 

 

 

8

 

 

 

 

 

M2500—Owner’s Manual 37

Image 41
Contents Mixing Console Nederland Netherlands Operating Notes Important InformationKeep This Manual For Future Reference Read the Following Before Operating M2500Page Introduction ContentsFeatures of the system Input channel section Control panelMonaural input channels AUX 1-AUX 14 controlsPAN control PRE switchesChannel assign switches PEAK/NOM/SIGNAL indicators ON/EDIT switch / ON, Check indicatorsPFL pre-fader listen switch Channel faderGain B control B switchStereo input channels BAL control If the ST switch is onIf a 1-2/3-4/5-6/7-8 switch is on Input a ST CH Input B Mono GROUP/AUX master section AFL after fader listen switchesAUX 1-6 section AUX 1-6master fadersAFL switch On switchGROUP/AUX Flip switch= Group GROUP/AUX Flip switch= AUXG1/A7-G8/A14 section Matrix switch Fader AFL after fader listen switchWhen AUX is selected GROUP/AUX Flip switchWhen Group is selected MATRIX/ST/MONO/LCR Stereo/monaural master section Matrix switchStereo section MONO/C sectionMatrix Monitor ST L/R controls Matrix sectionMONO/C control G1/A7-G8/A14 controlsMaster indicator Monitor signal priority orderMaster PFL switch Monitor sectionPhones jack +R switchPhones headphone control Oscillator on switch MONO/C switchTalkback/oscillator section MIC jackAUX 1-6 switch A7-14/G1-8 switchG1-8/A7-14 switch Meter select sectionStore switch Recall switchCheck switch Direct Recall 1-8 switchesPhantom Master indicator +15V/-15V/+12V indicatorsMeter bridge MONO/C level meterNominal input Rear panelInsert I/O jacks Input B jacks Stereo input channel input/ output jacksInput a jacks Input jacks AUX/GRP OUT jacks Master section input/output jacksGRP/AUX OUT jacks Matrix OUT jacksMonitor OUT jacks ST OUT, MONO/C OUT jacksSUB in Matrix jacks SUB in ST L/R, MONO/C jackPhantom Master switch Midi connectorsDC Power Input connector Lamp connectorModes of the scene memory function What is scene memory?Scene Memory function Using Direct Recall to recall a scene Operation in Normal modeRecalling a scene Storing a sceneChecking the contents of a scene you wish to recall Check mode operationEditing and storing the scene you are checking Press the Check key once again to return to Normal modeUtility items Utility mode proceduresBasic procedure in Utility mode Program change transmission/reception OFF/on/LoC Midi channelControl change transmission/reception OFF/GrP/on Program change reception omni on/off On/oFFControl No Channel Mute group Control change tableMute group Mute groupsDirect recall About the local control cir- cuit Using mute groupsError messages General specifications SpecificationsOutput specifications Input/output characteristicsInput specifications Included items Connector wiringOther Rear DimensionsFront Midi data format Midi Implementation Yamaha Corporation