The Triggers
4. Select the condition for activating the trigger:
Level moved from High to Low
Level Moved from Low to High
Level is High for:
Level is Low for:
Closing the circuit1 or the voltage exceeding its maximum defined value2 activates the trigger immediately
Opening the circuit1 or the voltage decreasing below its minimum defined value2 activates the trigger immediately
Circuit remains open1 or the voltage exceeding its maximum defined value2 and staying
there for a set period of time (see Figure 89); the trigger is activated on the first occurrence
Circuit remains closed1 or the voltage decreasing below its minimum defined value2 and staying there for a set period of time; the trigger is activated on the first occurrence
Figure 89: GPI/O Trigger Timeout (Digital Input)
5.Set the Timeout and click OK.
6.Select the GPI/O trigger from the list of available triggers (see Figure 90):
Figure 90: Selecting the GPI/O Trigger from the Available Triggers List
7. Add actions to the new trigger (see Figure 91).
Figure 91: Adding Actions to the GPI/O Trigger
1 Pullup checked
2 Pullup not checked
45