Nordyne M3RL Series Maintenance, Accessory Kits, Combustion Air and Vent System, Air Filter

Page 29

FURNACE ACCESSORY KITS

Kit

 

Order Number

A/C Coil Box

 

911969A

Side Return Air Kit

 

904003

Top Return Air Kit

 

904015

Sloped Roof VentilAire III Kit

914098

Sloped Roof VentilAire IV Kit

914229

Soffit VentilAire Kit

 

917201

Concentric Vent Termination Kit

903578

(for horizontal and vertical venting)

 

Horizontal Exterior Vent

 

 

Mounting Kit

3"PVC

902375

Neutralizer Kit - All Models

902377

Table 12. Accessory Kits

Gas Valve – The gas valve controls the flow of gas to the burners. When the gas valve is energized it automatically opens and regulates the gas pressure in the manifold.

Pressure Switch – The pressure switch veri- fies that the inducer is drawing the combustion gases through the heat exchanger. It also senses a blocked condensate drain condition.

Deck Limit Switch (Auxiliary Limit) – The deck limit protects the furnace filter tempera- ture from overheating when the motor has malfunctioned. If the deck switch opens, the power for the furnace will shut down (see Figure 29).

Supply Air Limit Switch – The supply air limit switch prevents the air temperature leaving the furnace from exceeding the maximum outlet air temperature.

Vent Safety Switch – The vent safety switch shuts the furnace down if the outlet flue gas temperature increases above 145°F. This switch protects the plastic flue system and the inducer from over-temperature conditions.

Flame Roll-Out Switch – This switch pro- vides flame roll-out protection to the furnace and combustion air inlet pipe.

MAINTENANCE

It is recommended that the furnace be checked yearly. At a minimum, this check should include the following items:

!WARNING:

To avoid electric shock, personal injury, or death, turn off the power at the disconnect or the main service panel before performing any maintenance.

!WARNING:

Holes in the vent pipe or heat exchanger can cause products of combustion to enter the occupied space. Replace the vent pipe or heat exchanger if leaks are found. Failure to prevent products of combustion from being circulated into the occupied space can crate poten- tially hazardous conditions, including carbon monoxide poisoning, that could result in personal injury or death.

Combustion Air and Vent System

Check the combustion air and vent pipe to ensure that it is not damaged, corroded or blocked by debris. Any damaged section of vent pipe must be replaced, and any obstruc- tion or blockage must be removed prior to operating the furnace.

Air Filter

An air filter is supplied with the furnace as shipped from the factory. Filters should be changed or cleaned monthly during the heating season. New or newly renovated homes may require more frequent changing until the con- struction dust has been removed.

29

Image 29
Contents Installation Instructions Page L 060 a a W Table of ContentsFurnace Specifications/Airflow Data Shipping WeightGeneral Top ViewGeneral Description Owner InformationManufacturer WARRANTY, OWNER’S Responsibilities Installation StandardsMinimum Clearances LocationCirculating AIR Supply Return AIR Provisions Duct ConnectorsDucted Return AIR Closet or AlcoveAIR Distribution Systems Duct Connector SelectionDuct Installation Installing Screw Down Duct CON- Nector Installing Platinum Series 14 Round Duct ConnectorCUT Duct Opening Finger Tabbed only Screw Down Platinum SeriesAlternate Attachment Methods Installing Finger Tabbed Duct CON- NectorsGeneral Install FurnaceVenting and Combustion AIR Requirements Furnace Must not be Common Vented with Other Appliances Venting RequirementsVent Termination Clearances for Direct Vent Furnaces Vent TableVent Pipe Material Vent Pipe InstallationHorizontal Venting Downflow FurnaceHorizontal Venting Drainage of Condensate from Furnace Alternate Horizontal Vent InstallationGAS Supply and Piping Furnace with Condensate Drain Trap AssemblyLeak Check ConversionHigh Altitude Derate To Turn Off Fuel Supply to the ApplianceTo Remove the Burner Orifices To Remove the Burner AssemblyTo Convert the Unit to the Alternate Gas Approximate Orifice Size for Natural and LP GasesConvertible Pressure Regulator Cap Lighting and Adjustment of the ApplianceLine Voltage Wiring Electrical WiringType of Fuel Manifold Pressure Completing the ConversionElectrical Data Low Voltage WiringVentilation START-UP and AdjustmentsStart-Up Procedure Verifying Firing Rate Shut Down ProcedureSequence of Operation Description of Components Verifying Operation of the Supply Air Limit SwitchGas Flow Rate Verifying Burner OperationAccessory Kits MaintenanceCombustion Air and Vent System Air FilterSystem Operation Information Condensate Drain AssemblyLubrication Blower CompartmentFurnace Fails to Operate Cooling ModeM3 Downflow Furnace Downflow Furnace Wiring Diagram Page Fuel Type INSTALLATION/PERFORMANCE Check List¢7082197¤

M3RL Series specifications

The Nordyne M3RL Series is a cutting-edge line of residential heating and cooling systems designed to enhance home comfort while emphasizing energy efficiency and reliability. Engineered with the latest technologies, the M3RL Series stands out as a premier choice for homeowners seeking optimal climate control, advanced features, and quiet operation.

One of the standout characteristics of the Nordyne M3RL Series is its high-efficiency performance. With Seasonal Energy Efficiency Ratios (SEER) that surpass industry standards, these systems deliver exceptional cooling power while using less energy. This efficiency not only translates to lower utility bills but also reduces the environmental footprint, making the M3RL Series an eco-friendly option.

Incorporating advanced inverter technology, the M3RL Series units operate at varying speeds, allowing them to adjust cooling and heating output to match the current demand. This feature ensures consistent temperature control while minimizing energy consumption. The systems are also equipped with a variable-speed compressor, which works in harmony with the inverter technology to provide seamless operation and quiet performance.

The M3RL Series showcases durability through its robust construction. The outdoor units feature a powder-coated finish to withstand the elements, while the indoor components are designed with high-quality materials to ensure longevity. The environmentally friendly refrigerant used in these systems further emphasizes Nordyne's commitment to sustainability.

Another notable aspect is the advanced control options available with the M3RL Series. Homeowners can choose from various thermostat solutions, including smart thermostats that offer remote control capabilities and programming features. This flexibility allows users to optimize their heating and cooling schedules, enhancing both comfort and efficiency.

In terms of installation, the M3RL Series is designed with versatility in mind. The compact and lightweight design of the units ensures ease of placement in various home layouts, while the comprehensive installation manuals and support from Nordyne make the process straightforward for HVAC professionals.

The Nordyne M3RL Series is truly a hallmark of modern home climate control, embodying efficiency, durability, and advanced technology. With its combination of high-performance features, user-friendly controls, and a commitment to sustainability, it provides an ideal solution for homeowners looking to enhance comfort while reducing energy costs. The M3RL Series represents a significant step forward in the evolution of residential heating and cooling systems.