Nordyne M3RL Series installation instructions M3 Downflow Furnace

Page 32

M3 Downflow Furnace

 

3

 

 

 

21

 

 

 

2

 

 

 

18

 

8

 

 

 

 

4

 

 

 

 

 

9

 

5

 

10

 

 

 

 

19

 

 

 

6

 

11

 

 

 

 

 

 

16

 

22

 

 

 

7

 

12

 

 

 

 

 

 

13

 

17

 

 

 

 

 

14

 

1

 

 

 

 

 

15

1

Door Assembly - Louvered

12

Ignitor Assembly

2

Filter Inside Door

13

Burner View Port

3

Blower Assembly

14

Main Limit Switch

4

Control Board

15

Coil Cabinet Assembly (Optional)

5

Pressure Switch

16

Flame Sensor (On Burner Box)

6

Flame Rollout Switch

17

Gas Valve

7

“J” Trap Hard Tube

18

Switch, On/Off

8

Low Voltage Transformer

19

Blower, Inducer

9

In Line Drain Assembly

20

Orifice (In Burner Box)

10

Junction Box

21

Aux. Limit

11

Vent Safety Switch

22

Burner Box

Figure 29. Location of Major Components

32

Image 32
Contents Installation Instructions Page Table of Contents L 060 a a WShipping Weight Furnace Specifications/Airflow DataGeneral Top ViewOwner Information General DescriptionInstallation Standards Manufacturer WARRANTY, OWNER’S ResponsibilitiesMinimum Clearances LocationCirculating AIR Supply Duct Connectors Return AIR ProvisionsCloset or Alcove Ducted Return AIRAIR Distribution Systems Duct Connector SelectionDuct Installation Installing Platinum Series 14 Round Duct Connector Installing Screw Down Duct CON- NectorCUT Duct Opening Finger Tabbed only Screw Down Platinum SeriesInstalling Finger Tabbed Duct CON- Nectors Alternate Attachment MethodsGeneral Install FurnaceVenting and Combustion AIR Requirements Venting Requirements Furnace Must not be Common Vented with Other AppliancesVent Table Vent Termination Clearances for Direct Vent FurnacesVent Pipe Installation Vent Pipe MaterialDownflow Furnace Horizontal VentingHorizontal Venting Alternate Horizontal Vent Installation Drainage of Condensate from FurnaceFurnace with Condensate Drain Trap Assembly GAS Supply and PipingConversion Leak CheckHigh Altitude Derate To Turn Off Fuel Supply to the ApplianceTo Remove the Burner Assembly To Remove the Burner OrificesTo Convert the Unit to the Alternate Gas Approximate Orifice Size for Natural and LP GasesLighting and Adjustment of the Appliance Convertible Pressure Regulator CapElectrical Wiring Line Voltage WiringType of Fuel Manifold Pressure Completing the ConversionLow Voltage Wiring Electrical DataVentilation START-UP and AdjustmentsStart-Up Procedure Verifying Firing Rate Shut Down ProcedureSequence of Operation Verifying Operation of the Supply Air Limit Switch Description of ComponentsGas Flow Rate Verifying Burner Operation Maintenance Accessory Kits Combustion Air and Vent System Air FilterCondensate Drain Assembly System Operation InformationLubrication Blower CompartmentCooling Mode Furnace Fails to OperateM3 Downflow Furnace Downflow Furnace Wiring Diagram Page INSTALLATION/PERFORMANCE Check List Fuel Type¢7082197¤