Dynacord 1600-3, 2200-3, 1000-3 owner manual Important Safety Instructions

Page 4

POWERMATE3

IMPORTANT SAFETY INSTRUCTIONS

The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated „dangerous voltage“ within the product’s enclosure that may be of sufficent magnitude to constitute a risk of electric shock to per- sons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintance (servicing) instructions in the literature accompanying the appliance.

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a dry cloth.

7.Do not cover any ventilation openings. Install in accordance with the manufacture’s instructions.

8.Do not install near heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or the grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. I the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.Only use attachments/accessories specified by the manufacturer.

12.Use only with the cart, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13.Unplug this apparatus during lightning storms or when unused for a long period of time.

14.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or orbjects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

15.Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.

16.To completely disconnect this equipment from the AC Mains, disconnect the power supply cord plug from the AC receptacle.

17.The mains plug of the power supply cord shall remain readily operable.

18.No naked flame sources, such as lighted candles, should be placed on the apparatus.

19.The product should be connected to a mains socket outlet with a protective earthing connection.

IMPORTANT SERVICE INSTRUCTIONS

CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

1.Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance.

2.Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains.

3.Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.

5.Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.Altering the circuitry without prior consent or advice is not legitimate.

7.Any work security regulations that are applicable at the locations where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.

8.All instructions concerning the handling of MOS-circuits have to be observed.

NOTE:

SAFETY COMPONENT (MUST BE REPLACED BY ORIGINAL PART)

WEEE RECYCLING/DISPOSAL INSTRUCTIONS

The Wheelie Bin symbol found on the product or in the manual indicates that this product must not be disposed of with other waste. It is in our category the manufacturer’s responsibility to properly dispose of their waste electrical and electronic equipment (WEEE) at the end of its life. Due to the differences in each EU country’s management of WEEE, please contact your local distributor. We are committed to facilitate our own electronic-waste-management-system, for the free of charge return of all EVI Audio GmbH products: Telex, DYNACORD, Electro-Voice and RTS. Arrangements are made with the dealer where you purchased the equipment from, for the returning of all unusable equipment at no cost, to the factory in Straubing, for environmental protective disposal.

4

Image 4
Contents PowerMate3 PowerMate 1000-3 1600-3POWERMATE3 Contents Inhalt Important Safety Instructions Introduction Warranty Installation and ConnectionsScope of Delivery, Unpacking and Inspection Open the lid as shown in following illustration Close the lid as shown in following illustration Controls, Indicators and Connections Input MonoMIC LineInsert Gain ControlLO CUT 80 HZ Voice FilterEQ Section FX 1/2 AUX 1/2MON 1/2 PANPFL SIG / PK IndicatorFader Input Stereo Stereo Input L/MONO RPowerMate Gain MICGain Line CD / USB InputFX 1/2 AUX 1/2 MON 1/2 BAL SIG/PKFX 1/2 FX ON/OFFFX 1/2 Sends Socket FX 1/2 Send ControlFX 1/2 to AUX 1/2 FX 1/2 to MON 1/2PK LED FX onAUX 1/2 MON 1/2AUX Post Feedback FilterMON 1/2 Fader PFL ButtonUSB Master with GEQ Master LED-DISPLAYMaster L/R Fader StandbyInputs Power AMP L/R Master a OUT L/RMaster B Outputs L/R Master B63 2TRACK in L/R 64 2TRACK to MasterREC Send & USB OUT Lamp 12V/5WDisplay with function keys 67 11-BAND Stereo Graphic EqualizerGraphic EQ to Master / MON 1/2 MenuStereo Power Amplifier TAPAmplifier Status Indicators PowerRear panel Midi IN/OUTIllustration 2-20 Connection of a passive speaker Effect mode Menu modeDisplay & functions Number DescriptionFX Control Setup Edit FX 1 / FXSetting Description AssignmentParameter Description Disable Parameter ValueEffects Effect group Description Preferable used withInstalling the USB driver Cubase LEPC-MIDI-Interface Status displayDisplay Description Examples of usage Playback Stereo Input PowerMate 1000 1600 2200Examples of usage Recording Live Midi tone generator and multi-effect unit Overview Setting up a standard PACabling Setting up PowerMate Cable ApplicationSoundcheck Monitor MIX Master Patchbay and different setup alternatives Maximum amount of passive speakersConnection of an external power amplifier Using the internal power amps for monitoringMono PA + Monitor Active 2-way stereo configuration Wichtige Sicherheitshinweise Lieferumfang, Auspacken und Überprüfen EinführungGarantie Aufstellen und Anschließen Öffnen Sie den Deckel wie in folgender Abbildung gezeigt Schließen Sie den Deckel wie in folgender Abbildung gezeigt MIC-BUCHSE Bedienelemente und AnschlüsseLINE-BUCHSE INSERT-BUCHSE GAIN-REGLERLO CUT 80 HZ-SCHALTER Voice FILTER-SCHALTERKlangregelung HI-, MID-, LO-REGLER FX 1/2-REGLERAUX 1/2-REGLER MON 1/2-REGLERPAN-REGLER MUTE-SCHALTERSIG / PK-ANZEIGE Stereo Input L/MONO R-BUCHSEN Gain MIC-REGLER EingangGain Line CD / USB-REGLER BAL-REGLER SIG/PK-ANZEIGEFX ON/OFF-BUCHSE FX 1/2 SENDS-BUCHSEN FX 1/2 SEND-REGLERPK-ANZEIGE FX ON-SCHALTERAUX 1/2 SENDS-BUCHSEN AUX POST-SCHALTERAUX SEND-FADER MON 1/2 OUTPUTS-BUCHSENMON 1/2-FADER Master L/R-FADER Master mit GEQSTANDBY-SCHALTER Inputs Power AMP L/R-BUCHSEN Master a OUT L/R-BUCHSENMaster B Outputs L/R-BUCHSEN Master B-REGLER63 2TRACK in L/R-BUCHSEN REC Send L/R-BUCHSENREC Send & USB OUT-REGLER Abbildung 2-17 Belegung der Lamp 12V/5W-Buchse Stereo-Leistungsverstärker Display mit Funktions-TastenMENU/ENTER-DREHENCODER Status Anzeige PROTECT-LEDRückseite Midi IN/OUT-BUCHSENDisplay & Funktionen Effekt-BetriebsartMenü-Betriebsart Nummer BeschreibungFX Control Setup Edit FX1 / FX2 MenuZuordnung Gewünschte Ergebnis erzielt werden Tieftonlautsprecher geeignetKann das LPN-Filter deaktiviert werden Parameter Beschreibung Power Control off deaktiviert Parameter WertEqualizer Routing LPN Processing HighEffekte Effektgruppe Beschreibung Bevorzugte AnwendungInstallation des USB-Treibers Funktionsanzeige im Display Anzeige BeschreibungInterface ist betriebsbereit USB OUT-Reglers MasterAnwendungsbeispiele Wiedergabe Anwendungsbeispiele Aufnahme MIDI-Klangerzeuger und Multieffektgerät Übersicht Aufbau einer Standard-PAVerkabelung Kabel Anwendung Aufbau Hauptmix Master Patchbay und verschiedene Aufbauversionen Maximale Ausbaustufe, PassivbetriebAnschluss eines externen Leistungsverstärkers Verwendung der internen Endstufen für MonitoreAbbildung 6-4 Mono PA + Monitor Aktiv Stereo 2-Weg System Specifications Property PowerMateSwitching Mode Power Supply µC controlled Phantom Power, switchable in groupsDimensions W x H x D, mm FS 11 Footswitch with LEDDimensions Block Diagram Trademarks POWERMATE3 POWERMATE3 Dynacord