VXI VT1538A user manual INPutTHResholdLEVel?, Level can be set to a resolution

Page 49

INPut:THReshold[:LEVel]

INPut:THReshold[:LEVel] <level>,(@<ch_list>) allows

programmatically setting the input threshold level for each input configured channel.

Parameters

 

 

 

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

 

Name

 

Type

Values

Units

 

 

 

 

 

 

 

 

 

 

 

level

 

numeric (float32)

-46 VDC to +46 VDC

none

 

 

 

 

 

 

 

 

 

 

 

ch_list

 

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments

<level> can be set to a resolution of .375V

 

 

. While input polarity is set to NORMAL, an input level higher than the threshold level is considered a logic one, and an input level lower than the threshold level is considered a logic zero. If input polarity is set to INVerted, an input level higher than the threshold level is considered a logic zero and an input level lower than the threshold level is considered a logic one.

Note The value sent for <level> will be rounded to the nearest multiple of 0.375 Volts. For instance, 5 would be 4.875, 10 would be 10.125, 9.5 would be 9.375, and 15 would be 15. The INP:THR:LEV? query will return the actual setting.

Related Commands: INPut:POLarity, INP:THR:LEV?

*RST Condition: INP:THR:LEV = 1.875

Send with VXIplug&play Function: hpe14XX_cmd(...)

INPut:THReshold[:LEVel]?

INPut:THReshold[:LEVel]? (@<channel>) returns the threshold level set for <channel>.

Parameters

 

 

 

 

 

 

 

Parameter

Parameter

Range of

Default

 

 

Name

Type

Values

Units

 

 

 

 

 

 

 

 

channel

string

100 - 163

none

 

 

 

 

 

 

 

 

 

 

 

 

 

Comments <channel> must specify a single channel.

Agilent E1538A Enhanced Frequency/Totalize/PWM SCP 45

Image 49
Contents VT1538A VXI Technology, Inc Introduction Support Resources User’s and Scpi Programming Manual Page About this Manual Agilent E1538A Enhanced Frequency/Totalize/PWM SCPIntroduction Identifying the Plug-on Important Switch Location and Example Settings Setting Configuration SwitchesConnecting To The Terminal Module InstallationE1419A Option 11 Terminal Module Connections Recommended Signal ConnectionsRecommended Connections and Voltage Limits Input and Output CharacteristicsE1538A Input/Output Characteristics VRS Mode Input Operation SCP Channels 0 & 1 onlyShows the VRS mode input characteristics Programming With Scpi CommandsSetting the Input Threshold Level Configuring I/O DirectionInppol Norm Determining the Input Threshold LevelTo set channels 40 through 43 to input digital states Reading Static Digital StateInit SENSDATACVT? @44 Totalize Positive or Negative Edge State ChangesAbout Period Frequency Measurements SENSDATACVT? @45 SENSDATACVT? @45 Agilent E1538A Enhanced Frequency/Totalize/PWM SCP Agilent E1538A Enhanced Frequency/Totalize/PWM SCP Sensfuncquad 0,@148,149 Sense Quadrature PositionRPS Sense Rotational Velocity Example of Rotational Velocity SenseOutput Static Digital State Controlling Output PolarityVariable Width Pulse Per Trigger Variable Width Pulse Train PWM Variable Frequency Fixed Width Pulse Train FM Variable Frequency Square-Wave Pulse Train Rotationally Positioned Pulse Output Rotational Pulse Command Usage Algupdate Init RST Sensfuncrvel 12,MISS,@140 Example of variable position, preset widthVariable Position, Width Preset by Time Example of variable width by angle, preset position Fixed Position, Variable Width by Angle Example of variable width by time, preset positionALGSCALAR’ALG1’,’Width2’,.010 Stepping mode values Stepper Motor Control Use the commandSensfuncvolt @100 Full Step Mode, Full and Half Speed, 4-Channel Page RST and *TST important Command Syntax For newer Units only Scpi Command ReferenceCommand Syntax For newer Units only Discussed INPutPOLarity? INPutPOLarityParameters CommentsINPutTHResholdLEVel Level can be set to a resolutionINPutTHResholdLEVel? OUTPutPOLarity? OUTPutPOLaritySend with VXIplug&play Function hpe14XXcmdReal64Q SENSeFREQuencyAPERture SENSeFREQuencyAPERture? Related Commands SensfreqaperSENSeFREQuencyLIMitLOWer Init SENSeFREQuencyLIMitLOWer? Related Commands INPutPOLaritySENSeFUNCtionCONDition SENSeFUNCtionPERiod SENSeFUNCtionFREQuencySENSeFUNCtionQUADrature SENSeFUNCtionPWIDthSENSeFUNCtionRVELocity RPS SENSeFUNCtionTOTalize SENSePERiodAPERture SENSePERiodLIMitUPPer SENSePERiodAPERture?Init SENSePERiodMODE SENSePERiodLIMitUPPer?SENSePERiodMODE? Related Commands SENSePERiodMODESENSePERiodNPERiods SENSePERiodRANGeUPPer SENSePERiodNPERiods?Send with VXIplug&play Function hpe14XXcmdInt32Q SENSePERiodRANGeUPPer? SENSeTOTalizeRESetMODERST Condition is Send with VXIplug&play Function hpe14XXcmd SOURceFMSTATe SENSeTOTalizeRESetMODE?Send with VXIplug&play Function hpe14XXcmdInt16Q SOURceFMSTATe?SOURceFUNCtionRPULse SOURceFUNCtionSHAPePULSe SOURceFUNCtionSHAPeCONDitionSOURceFUNCtionSTEPper SOURceFUNCtionSHAPeSQUareComments Send with VXIplug&play Function hpe14XXcmd Relationship of minvel, and maxvel Usage See Stepper Motor Control on SOURcePULMSTATeSOURcePULSePERiod SOURcePULMSTATe?SOURcePULSeWIDTh SOURcePULSePERiod?SOURceRPULsePOSitionANGLe SOURcePULSeWIDTh?33,554,430 to 33,554,430 SOURRPULseVARType SOURceRPULsePOSitionANGLe?Usage SOURceRPULseWIDThANGLe SOURRPULseVARType?SOURceRPULseWIDThTIME SOURceRPULseWIDThANGLe?00000787 to SOURceRPULseWIDThTIME? General Specifications SpecificationsFrequency Measurement Pulse Width Measure Rotational Pulse Source