[SENSe:]PERiod:LIMit:UPPer?
[SENSe:]PERiod:LIMit:UPPer? <channel> returns the upper period limit currently set for <channel>
Parameters
|
|
|
|
|
|
| Parameter | Parameter | Range of | Default |
|
| Name | Type | Values | Units |
|
|
|
|
|
|
|
| channel | string | 100 - 163 | none |
|
|
|
|
|
|
|
|
|
|
|
|
|
Comments •
•
SENSe:PERiod:MODE
<channel> must be a single channel on an E1538A SCP.
RETURNS: .004 to 60, Type is float32.
SENSe:PERiod:MODE <mode>,(@<ch_list>) selects the measurement
interval mode the SCP will use to measure the signal period. This can be set as a fixed amount of time (APERture), or a fixed number of signal periods (NPERiods).
Parameters
| Parameter | Parameter | Range of | Default |
|
| Name | Type | Values | Units |
|
|
|
|
|
|
|
| mode | discrete (string) | APERture NPERiods | none |
|
|
|
|
|
|
|
| ch_list | string | 100 - 163 | none |
|
|
|
|
|
|
|
|
|
|
|
|
|
Comments • The SENS:PER:APERture command sets the aperture value. The SENS:PER:NPERiods command sets the nperiods value.
•<ch_list> must be channels on E1538A SCPs.
•Related Commands: SENS:PER:APERture, SENS:PER:NPERiods, SENS:FUNC:PER, SENS:PER:LIM:UPPer
•*RST Condition: is “APERture”.
•.Send with VXIplug&play Function: hpe14XX_cmd(...)