SONOSAX SX/S USER MANUAL | Seite 14 von 22 |
The Tape / direct switch selects between monitoring the Audio signal before the tape or after the tape
The Tape return rotary switch on the extension box selects the tape return source.
Configurations: |
|
|
|
DIP Switch |
|
|
|
Position | Function | Factory Setting | Switch |
1 | Manual / Tape direct | Automatic | Off |
2 | Boom active | Switched | Off |
3 | Call LED momentary | Lamp on | Off |
4 | 27 Hz Slate tone | Off | Off |
Wiring of the 6 Neutrik connector (Boom Box connection)
Pin nb | Cable nb | Cable | Function |
6 | 2 | Cable call (GND) | CALL |
5 | 2 | Brown | Hi Mic Boom |
4 | 2 | White | Low Mic Boom |
3 | 1 | GND | GND |
2 | 1 | Red | Right channel H.phones |
1 | 1 | White | Left Channel H.phones |
Jumper positions:
{
{
{
The
6.15 SX022241 SX-S Stereo analog level & Phase meter
This module consists of two very high quality meter movements for the Left and Right channels. The meter scales can be illuminated with two intensities. The meters can be switched to indicate as VU meters or as
6.16 SX022270 SX-S Extension module
This module contains the SX022241 Stereo Analog Level & Phase Meter, plus the monitoring and communication functions, (including MS decoding). It is shipped with the necessary Neutrik
file://D:\Z_Library\Webcopy\sonosax\SXS\sxsume.html | 26.08.2004 |