SONOSAX SX/S USER MANUAL | Seite 4 von 22 |
{If necessary change the batteries. Using the Sonosax external power supply:
IMPORTANT : Before turning on the unit, make sure the voltage selector is correctly positioned at either 110V or 220V depending on local current supply. If needed, change selector position by using a screwdriver, a ball point pen or similar instrument. At 110V, the mixer may be powered from 100 to 125V , 50 to 60 Hertz; at 220V, from 200 to 260V, 50 to 60 Hertz.
Newer
{The POWER button on the master module should not be pressed while using the external power supply or while charging accumulators.
{The GND button separates the
2.2Using an external power supply
Apply current indicated (see 1.6) between points 1 (+) and 2 (0V) of the LEMO connector. Do not press the "POWER" button while using an external power supply or while charging accumulators.
2.3 Battery test
When BATT TEST
2.4 Low charge alarm
When the average charge per cell reaches 1.05V, the two LEDs will automatically start to blink. This alarm means that about 10 to 20 minutes remain before the mixer automatically turns off. This
2.5 Charging the NiCd batteries
WITH SONOSAX SX-S POWER SUPPLY :
This external accessory will automatically charge the NiCd batteries while the mixer is being used. Simply press the charge 0,4A button. The green "CHARGE" LED on the power supply as well as the green LED on the Master Module should light up. Nominal charge current is 400mA and nominal charging time is 15 hours.
WITH ANOTHER EXTERNAL POWER SUPPLY :
Apply current charge of 400mA to pin 3 of the LEMO connector. Nominal charging time is 15 hours.
IMPORTANT: Never charge
RETURN TO TABLE OF CONTENTS
3.INPUT MODULE (after serial nb 16579)
file://D:\Z_Library\Webcopy\sonosax\SXS\sxsume.html | 26.08.2004 |