Compex Systems SX-V, SONOSAX SX-S user manual Seite 16 von, Procedure, Optional

Page 16

SONOSAX SX/S USER MANUAL

Seite 16 von 22

{SX981134 Conical head screw M3x8 (4x)

{SX642403 24 kOhms 1% R0805 Resistor (2x)

{SXS351220 22pF 1% C0805 (1x)

{SXS644990 49,9 Ohms 1% R0805 Resistor (1x)

{SXS641503 15 kOhms 1% R0805 Resistor (1x)

{SX860131 Bantam mini-jack pre-wired (1x)

{SX140002 NPN-Transistor BC 550 C

When installing an SX022270 SX-S Extension Module in an SX-S mixing console with serial-number 16585 or lower R-64 and R-65 on the extension module operator board need to be replaced by 24kOhms 1% SMD R0805.

7.2 Procedure

On the Master Board (solder side) solder the 6 conductors of the ribbon cable(see PCB Layout)

Change Q1 (BC337) on the Masterboard with BC 550C (SX140002).

Mount the 12-pin Hirose socket in place of the last Input's 3-pin Neutrik.

Install the 6-pin Neutrik socket next to the 12-pin Hirose socket.

Install the Extension module beside the master board and connect the wires asindicated on the PCB Layout. Do not forget to install the additional 26-pin connector on the SX-S10 ribbon cable.

SX-S 10: Disconnect the Aux. XLR 3-pin male and replace it with SX860141,socket 1/4'' with 150mm shielded cable and Dubox case.

SX-S 6 SX-S 8: Remove the existing 1/4'' Jack, unsolder the connections on the Masterboard and reconnect to the Bantam Jack with cable provided. Install the SX860141, socket 1/4'' with 150mm shielded cable and Dubox case.

Click here for Illustration of INTERNAL connections, ajustments and switches

Click here for Master Module PCB Layout

NOTE:The ribbon cable connects to the PCB (from Left to right) Yellow - Brown - Orange - Green - Red - Blue.

Connections of the 6 pole Flatcable

Brown Cable

1

PFL-BUS-left

Red Cable

2

MASTER-BUS-right

Orange Cable

3

PFL-BUS-right

Yellow Cable

4

Auxiliary BUS

Green Cable

5

PFL Control-CDE (sense)

Connected to pin No 1 OP-7 Connected to pin No 1 OP-3 Connected to pin No 7 OP-7 Connected to cursor Aux potentiometer

Connected to point R-6/R-5/collector of Q1

Blue Cable

6

MASTER-BUS-left

Connected to pin No 7 OP-3

7.3 Optional

External Slate MIC for the Mixer's operator

file://D:\Z_Library\Webcopy\sonosax\SXS\sxsume.html

26.08.2004

Image 16
Contents Table of Contents IntroductionRemoving the battery compartment Seite 2 vonPreparation Closing the coverSeite 3 von Operating InstructionsUsing an external power supply Battery testLow charge alarm Seite 4 vonSonosax SX-S Input Module Specifications Seite 5 vonSeite 6 von Seite 7 von Seite 8 von Standard Input ModuleSeite 9 von Master ModuleSeite 10 von EXT or Tape returnOscillator IntroductionExtension module includes Seite 11 vonExtension box Seite 12 von Seite 13 von Seite 14 von 15 SX022241 SX-S Stereo analog level & Phase meter16 SX022270 SX-S Extension module Seite 15 von 17 SX022251 SX-S Extension box18 SX022260 SX-S Boom box 19 SX922120 SX-S Boom box cableSeite 16 von ProcedureOptional Seite 17 von Cables for Boom Operator with tbk mic transmitterSeite 18 von Four Channel Matrix ModuleSeite 19 von Additional AUX ModuleMode switch upper right corner Operating level switchOutput selector switch Seite 20 vonSeite 21 von Sonosax SX-VSeite 22 von Tips on Using Your MixerVCA option