| IN 16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 |
|
|
|
|
|
|
| ||||
iDR |
|
| IN 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
| IN | OUT |
|
|
|
|
|
|
|
|
|
| OUT 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
|
| OUT16 | 15 | 14 | 13 | 12 | 11 | 10 | 9 |
IN |
|
|
|
|
|
|
|
|
Fully expanded
Use CAT5 STP cable. A pair of standard 2 metre cables is provided with each expander. Maximum cable length is 250 metres. This means that the expander units can be used for remote audio over CAT5 cable.
|
| AUDIO | IN 16A | 15A | 14A | 13A | 12A | 11A | 10A | 9A | |
OUT IN | OUT |
|
|
|
|
|
|
| |||
iDR | Unit A |
| IN 8A | 7A | 6A | 5A | 4A | 3A | 2A | 1A | |
|
| IN OUT |
|
|
|
|
|
|
| ||
|
|
|
| OUT 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
iDR | Unit B | IN 8B | 7B | 6B | 5B | 4B | 3B | 2B | 1B | ||
|
| OUT |
|
|
|
|
|
|
| ||
|
|
|
| OUT 8 | 7 | 6 | 5 | 4 | 3 | 2 | 1 |
|
|
| OUT 16B | 15B | 14B | 13B | 12B | 11B | 10B | 9B | |
DR | IN |
|
|
|
|
|
|
|
|
Expanded multiple iDR-8 system This diagram
shows an iDR system with two
Use CAT5 STP cable. Maximum cable length is 250 metres. Maximum audio matrix is 16x16. The audio link cable carries 8 channels. This can provide a distributed system with 8 common channels and 8 local channels at each unit.
31