Working with the iDR System Manager

Having established a connection between your PC and the iDR-8you can run the iDR System Manager application and start to configure the unit.

Start the iDR System Manager from the Start / Programs

/Allen & Heath menu. To open a new session click on the blue icon, press Ctrl+N, or open the New item in the File menu. All iDR units currently available are shown in the list. Select the one you want to work with. Click OK to open its session. You can have more than one session open at the same time. Each has its own window. The status bar at the bottom of the window displays which unit the window is working with.

For TCP/IP communication the rear panel LINK indicator remains lit once communication is established. The TX indicator next to it flashes to show when data is being communicated between the PC and iDR-8when the software is running. If the LINK indicator is off check the setting of the MDI/X switch and the IP addresses.

Setting the Time and Day Clock

Before starting to configure the unit, check that the time and day of week are correctly set. Depending on the current LCD settings these may or may not be displayed. There are two ways to change the settings:

Front panel menus With the face plate removed, access menu *2 Clock and menu *3 Day of Week.

iDR System Manager software Click on the Edit menu Set Time item. You can manually enter the settings or use the Sync to PC button to load in the current PC time and day settings.

Archiving and Loading Configurations

CONFIGURATION

DR-8

OPENARCHIVE

.cfg FILE

The way the iDR-8is set up and the contents of any patches which have been created is stored as a ‘configuration’. It can be archived as a .cfg file on your PC. Any number of configurations can be named and stored. You can load a configuration back into the unit using the iDR System Manager. Refer to the section about Configurations and Patches later in this user guide and the iDR System Manager Help file for more details.

We recommend that you regularly archive the configuration when you are preparing and installing iDR systems, making changes to system settings on site, or updating the unit operating software.

The iDR-8is shipped with a DEFAULT configuration loaded. An additional RESET configuration is provided. These provide a useful starting point for configuring the system by clearing the memories and resetting the controls. DEFAULT provides a quick start for basic testing of the hardware and cabling before working with the configuration software.

To archive or open a configuration start iDR System Manager and use the File menu Archive Configuration (Ctrl+S) and Open Configuration (Ctrl+O) items or the toolbar icons.

26

IDR-8User Guide

Image 26
Contents IDR-8 Limited One Year Warranty Conditions Of WarrantyThis appliance must be earthed Important Safety Instructions Read FirstImportant Mains Plug Wiring Instructions IDR-8User GuideIntroduction Contents Welcome to the iDR-8 DR-8Daisy chain iDR-8 units Any number may be Main FeaturesIDR-8 main processing unit 2U, 8 mic/line Stereo audio monitor with front panelExpander status LEDs These display Front Panel OverviewFront panel RS232 port This is used for Rear Panel Overview Monitor in L Monitor OUT LSystem Processing Overview IDR-8User Guide Page Getting Started Check the Contents IDR System Manager Software BundleInstalling the iDR-8 IDR-8 Main UnitEarthing Turning the iDR-8 On and Off Parameters restored on power-up The iDR-8Starting Offline with iDR System Manager Software Checking the iDR-8 Operating Code Version Updating the iDR-8 Operating CodeIDR-8 Setup Menus PPP SetupRebooting the iDR-8 Accessing the iDR-8 Setup MenusChecking the Current Settings and Status Changing the Unit NameGetting Started Checking the Hardware DR-8RS232 COM Port Communicating with the iDR-8Network Port Communicating Using a TCP/IP Connection How to get the MAC address Connecting the iDR-8 Direct to the PCConnecting the iDR-8 to a Network Connect the PC to the iDR-8 Plug the PC Ethernet portChanging the iDR-8 PPP settings Go to menu *6 PPP Communicating Using a Dial Up ConnectionSetting up a Dial-up Connection Setting up the PC dial-up connection You needStarting the iDR System Manager Connecting the iDR-8 to a ModemDial up the iDR-8 using the remote PC Open up Connect the iDR-8 to the modemWorking with the iDR System Manager Setting the Time and Day ClockArchiving and Loading Configurations Start the iDR System Manager from the Start / ProgramsXLR Analogue Inputs and Outputs Input Source window From within the InputMonitor TRS Input and Output The monitor is Monitor Headphones Output This followsMonitor Inputs and Outputs Using the Monitor as Additional Channels Daisy chaining iDR-8 monitors The activeTurning the expander on or off Turn the unit on Adding the iDR-in and iDR-out Audio ExpandersCheck the connections The iDR-inAUDIO OUT Checking for expanders You can use the frontExpanded multiple iDR-8 system This diagram Linking iDR-8 Units SlaveUnit a Connecting to the iDR-8 The iDR-8communicates Adding the iDR-switch ExpanderChecking for iDR-switch expanders You can Connectors and grounding Pluggable Phoenix Using the switch closure inputs The input isUsing the logic outputs Each output is opto Selecting the Communications Options Click on MIDI, SysNet and PL-Anet PortsSysNet IDR-8 Memory System IDR-8 unit settings These areConfiguration file settings These are Only store the parameters you need For your Starting with the PatchesDecide your system starting point Assign Technical Specification DR-8Application DR-8Headphones IDR-8 Installer Front PanelIDR-switch Front Panel DescriptionPower Supply IDR-switch InputsIDR-switch Logic Outputs Network PortClock Soft SwitchesSoftware NamingLevel Control DelaySignal Generator Fader GroupsFactory default patch parameters Factory default unit settingsFactory default configuration settings Template for Allen & Heath iDR-8 Front Panel Key Label