Aviom MH10m, MH10f manual MH10 Configuration Errors, Data Loops

Page 34

all audio inputs from the stage (ports 1-8) for use in a monitor console or in a recording or broadcast room.

All Cat-5e network cables shown in the example diagrams can be up to 400 feet (120 meters) long. Fiber optic cable length will depend upon the type of SFP device used (single- or multi-mode). Always use the same type and specification SFP transceivers in each MH10f.

MH10 Configuration Errors

Data Loops

When using multiple MH10/MH10f Merger Hubs in a digital network, never connect a pair of ports (two cables) between MH10/MH10f devices other than ports 9-10 in Manual Mode Configuration C. Doing so will cause an A‑Net data loop. Only Manual Mode, and its Configuration C specifically, can use a pair of Cat-5e or fiber cables connected between ports 9 and 10 in a backup/redundant cable setup.

Changing from Manual Mode to Auto Mode

When changing from a Manual Mode setup using two MH10/MH10f Merger Hubs in Configuration C to an Auto Mode setup, make sure that the backup/redundant cable connected between port 9 or 10 on each MH10/MH10f is disconnected before changing the network setup to avoid a data loop. Only one cable (Cat-5e or fiber) should be connected between ports 9-10 when the MH10/MH10f is being used in any configuration except Manual Mode Configuration C.

26MH10 Configurations

Image 34
Contents User Guide Certifications Iii Important Safety Instructions Warranty Information Aviom, Inc. Limited Warranty Table of Contents Viii EtherCon Connector FeaturesWelcome LC Connector SFP ModuleFirmware Update Cat-5eAbout A-Net Sample Rate Minimum MaximumControl Data ClockingNet Ports Support For Pro16 Series Products AC Line Conditioning AC PowerRack Mounting Cleaning VentilationFront Panel Components  MH10 Rear Panel MH10f Rear Panel  Front Panel Features Network Mode IndicatorNet Port LEDs Net LEDManaged Mode LED AC Power Rear Panel FeaturesBackup DC Power MH10f Net Ports Manual Mode Configuration Button MH10 Configurations Auto ModeR G E Manual Mode Configuration a Merge AllStage TAG E Configuration C Merge Configuration C Example Monitor Console MH10 Configuration Errors Data LoopsSpecifications Fiber Optic ModesDimensions Index SFP Port A, B. See A-Net Port See A-Net Ports