Alesis DM5 manual Setting UP, Unpacking and Inspection, AC Power Hookup, Chapter

Page 6

Setting Up: Chapter 1

CHAPTER 1

SETTING UP

UNPACKING AND INSPECTION

Your DM5 was packed carefully at the factory. The shipping carton was designed to protect the unit during shipping. Please retain this container in the highly unlikely event that you need to return the DM5 for servicing.

The shipping carton should contain the following items:

DM5 with the same serial number as shown on shipping carton

AC Power Supply Adapter

This instruction manual

Alesis warranty card

It is important to register your purchase; if you have not already filled out your warranty card and mailed it back to Alesis, please take the time to do so now.

AC POWER HOOKUP

The DM5 comes with a power adapter suitable for the voltage of the country it is shipped to (either 110 or 220V, 50 or 60 Hz). With the DM5 off, plug the small end of the power adapter cord into the DM5’s [POWER] socket and the male (plug) end into a source of AC power. It’s good practice to not turn the DM5 on until all other cables are hooked up.

Alesis cannot be responsible for problems caused by using the DM5 or any associated equipment with improper AC wiring.

LINE CONDITIONERS AND PROTECTORS

Although the DM5 is designed to tolerate typical voltage variations, in today’s world the voltage coming from the AC line may contain spikes or transients that can possibly stress your gear and, over time, cause a failure. There are three main ways to protect against this, listed in ascending order of cost and complexity:

Line spike/surge protectors. Relatively inexpensive, these are designed to protect against strong surges and spikes, acting somewhat like fuses in that they need to be replaced if they’ve been hit by an extremely strong spike.

Line filters. These generally combine spike/surge protection with filters that remove some line noise (dimmer hash, transients from other appliances, etc.).

Uninterruptible power supply (UPS). This is the most sophisticated option. A UPS provides power even if the AC power line fails completely. Intended for computer applications, a UPS allows you to complete an orderly shutdown of a computer system in the event of a power outage, and the isolation it provides from the power line minimizes all forms of interference—spikes, noise, etc.

DM5 Reference Manual

5

Image 6
Contents Alesis DM5 HOW to USE this Manual Introduction DM5 Reference Manual Contents Midi Functions Appendix a TROUBLE-SHOOTINGMidi Implementation Chart External TriggeringUnpacking and Inspection Setting UPAC Power Hookup ChapterAbout Audio Cables Basic Audio HookupMidi Hookup To turn on the Midi Thru parameterExternal Triggers Hookup Powering UP Your First Session With the DM5Playing the Demo Sequence Auditioning Internal Programs WHAT’S a Drum SET?Playing the DM5 Selecting the Midi ChannelChoosing Voices in a Drum SET Storing AN Edited Drum SET Naming a Drum SETRecalling the Factory Drum Sets Midi OUT/THRU Mode To turn on Midi Thru ModeConnections Example 1 Using a Midi Keyboard To set the Midi ChannelTo set the Root Note Example 2 Using a Midi Sequencer Local Mode To turn the Local Control offExample 3 Using TWO or More DM5 Modules To turn the Midi Overflow Mode onExternal Triggers To setup the external triggers Crosstalk To Set the Crosstalk valueTo set the Decay value To set the Noise valueFootswitch Hookup To set the Footswitch ModeVoice OverviewBasic and Definitions Random VoicesDM5 Polyphony Midi Note RangeAbout the User Interface Reading the DisplayFunction Buttons ButtonsMULTI-PAGE Functions Store Button Drum Note SelectionEditing Parameter Values Preview ButtonFunction Buttons TuneMIX OutputOutput Options Drum SET EXT TrigGroup Midi Copying a NOTE’S Parameters to AnotherMidi Functions Drum SET Root NoteMidi Channel Program Change Enable Local ControlControllers Enable Program Change Table Saving Data VIA MidiTo edit the Program Change table Receiving Data from Another Midi Device To back upExternal Triggering OverviewAbout Trigger Parameters Page Example Trigger Selection Trigger Note Assignment GainVelocity Curve Method One Method TwoCrosstalk Footswitch Mode DecayNoise Understanding HI HAT Pedal Mode Output Sensitivity Trigger PlacementTips on Triggering from Acoustic Drums MountingFor head mounting If you play with a fairly tight batter head, try thisIf you play with a looser head, try this For shell mountingMounting Hardware and Configuration MufflingLarge Toms External Triggering DM5 Reference Manual MAINTENANCE/SERVICE TROUBLE-SHOOTINGTROUBLE-SHOOTING Index RE-INITIALIZINGRefer ALL Servicing to Alesis MaintenanceObtaining Repair Service Customers in the USA