INSTALLATION

shut off the supply of gas within 5 - 10 minutes. Tampering with the switch can result in carbon monoxide (CO) poisoning and possible death.

If the heater turns off because of lack ofdraftduringthespillagetest,check for the cause and if necessary, seek expert advice.

The thermally actuated safety switch will automatically reset after it has reduced in temperature. The switch will continue to cycle until the draft problem is corrected. DO NOT BYPASS OR DISCONNECT THIS SWITCH.

3) Using the trim clips provided, join the left side gold trim (the one with the ON/OFF switch and variable speed FAN switch) to the top gold trim. See diagram 2. Repeat this step for right side.

tighten top screw only

Trim Clips

Rear View

Diagram 2

Diagram 4

FACEPLATE AND TRIM

INSTALLATION

Hint: Before doing the faceplate installation, leave the Insert out approximately 4" so wires may be hooked up more easily.

1)Lay the faceplate panels fl at, face down on something soft so they don't scratch.

2)Take the top faceplate and align the holes in it with the holes in the side panels. Attach, using the screws provided. See diagram 1.

4)

Place the trim on the assembled faceplate

 

panels, aligning the wires from the switches

 

with the notch in the left side faceplate

 

panel.

 

The power cord should be run behind the

 

faceplate panel.

5)

Push the Regency logo plate into the two

 

holes in the bottom left corner of the face-

 

plate.

6)

Secure the brass trim to the faceplate by

 

drilling a 1/8" hole through into the faceplate

 

side fl ange, using the hole in the brass trim

 

as a guide. Now fasten with the two brass

 

plated screws provided.

7)

Lift the assembled faceplate up and over the

8)Fan Switch wires: Connect the plug end from the fan switches to the matching plug from the unit. See Diagram 5. Make sure the plugs are pushed together as far as they can go. Push the connection into the hole in the side of the insert so it is locked into place.

9)ON/OFF wires: Hook up the ON/OFF wires to the switch on the left side trim. Diagram 5.

Screws

Right

Side

Tabs

Top

Hinged Louvers

top of the insert and then lower it down so the

faceplate tabs are in line with the faceplate

brackets. See diagram 3. Once everything

is properly lined up you can tighten the 4

screws on the faceplate brackets. See

diagram 4.

Diagram 5

Diagram 1

Note: The holes in the top panel are slightly larger than the holes in the side panel to facilitate easier installation.

Hint: Don't tighten the screws down completely at this point, fi rst do a trial fi t to the unit. Make any necessary adjustments and when it fi ts properly then tighten down the screws.

Diagram 3

Note: If you are making custom face-plates, you must use the faceplate louvers. Failure to do so will void the certifica- tion on your unit. The faceplate lou- vers can be purchased separately.

Regency U41-3 ULTIMATE Gas Fireplace Insert

11

Image 11
Contents 908-727c 07/17/06 U41 Gas InsertTo the NEW Owner Regency GAS Fireplace InsertTable of Contents Do not Remove this Label Safety LabelMA Code CO Detector RequirementsInstallation Clearances Installation Checklist Non-combustible Hearth Extension High Elevation Combustible Mantel Clearances Venting GAS ConnectionDraft Hood Connection Combustion Ventilation AIR Test for Flue Spillage GAS Pressure TestAeration System Faceplate panel Faceplate and Trim InstallationDoor Installation Packaged Separately LOG InstallationManufacturer Final CheckWiring Diagram Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Readbefore LightingNormal Operating Sounds GAS Appliances MaintenanceMaintenance Instructions GOLD-PLATED Doors LOG ReplacementLatch Adjustment Glass ReplacementReplacing fan FAN MaintenanceMain Assembly Parts ListBurner & Logs Description Faceplate & TrimConditions WarrantyInstaller Please complete the following information