OPERATING INSTRUCTIONS

OPERATING

INSTRUCTIONS

Before operating this appliance, proceed through the following check list.

1)Read and understand these Instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the three door glass pieces are in place. Never operate the appliance with any of the door glass removed or with the door open. Do not strike the glass or slam the door shut.

Warning: Do not operate appliance with glass front removed, cracked orbroken.Replacementoftheglass should be done by a licensed or qualified service person.

5)Verify that all venting and the cap is unob- structed.

6)Verify log placement. If the pilot cannot be seen when lighting the unit - the logs or the embers have been incorrectly positioned.

7)The unit should never to turned off and on without a minimum of a 60 second wait.

8)When lighting the appliance, the inside of the glass may fog up. This will burn off after a few minutes of operation.

DO NOT BURN THE APPLIANCE WITH THE DOOR OPEN.

LIGHTING

PROCEDURE

IMPORTANT: Gas cock knob cannot be turned from "PILOT" to "OFF" unless it is partially depressed.

1)Open the left side door when lighting the pilot,butoncethepilotislit,DONOToperate the unit with the front glass door open.

2)Openthebottomlouverassemblybyturning the wing nut and swinging the louvers out. (See page 8 for diagram.)

3)If the control knob is in the "OFF" position proceed to Step 5.

4)Push in gas control knob slightly and turn clockwise to "OFF".

5)Wait fi ve minutes to allow gas, that may have accumulated in the main burner compartment, to escape. If you do smell gas, follow the instructions on the front of this manual. If you don't smell gas continue on to the next step.

6)Turn the gas control counterclockwise to "PILOT".

7)Push in control knob all the way and hold in. Immediately push black button on spark igniter until pilot lights. Continue to hold the control knob in for approximately one minute, then release the gas control knob. The pilot fl ame should continue to burn. If thepilotdoesnotremainlit,repeatoperation allowing a longer period before releasing gas control knob.

8)Turn gas control knob counterclockwise to "ON".

9)Use rocker switch to operate main burn- er.

10)Rotate the variable fl ame control to adjust the fl ame height higher or lower.

11)Close the bottom louver assembly and tighten the wingnut.

12)The door must be closed when operating the unit.

Knob cannot be turned from "PILOT" to "OFF" unless knob is pushed in slightly.

Do not force.

SHUTDOWN

PROCEDURE

1)Use the rocker switch to turn off the main burner.

2)Open the bottom louver assembly by turn- ing the wing nut and swinging the louvers out.

3)Push in the gas control knob slightly and turn clockwise to "OFF". Do not force.

4)Disconnect all electric power to the appli- ance if service is to be performed.

FIRST FIRE

The fi rst fi re in your stove is part of the paint curing process. To ensure that the paint is properly cured, it is recommended that you burn your fi replace for at least four (4) hours the fi rst time you use it with the fan on. When

rst operated, the unit will release an odour caused by the curing of the paint, the burning off of any oils remaining from manufacturing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours.

The glass panel may require cleaning after the unit has cooled down.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

Note: When the glass is cold and the appli- ance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE.

AUTOMATIC

CONVECTION FAN

OPERATION

The fan operates automatically, turn the knob on the side of the faceplate to adjust to the desired speed. The fan will turn on as the stove comes up to operating temperature. After the unit has been turned off and the unit cooled to below a useful heat output range the fan will shut off automatically.

Regency U41-3 ULTIMATE Gas Fireplace Insert

15

Image 15
Contents 908-727c 07/17/06 U41 Gas InsertTo the NEW Owner Regency GAS Fireplace InsertTable of Contents Do not Remove this Label Safety LabelMA Code CO Detector RequirementsInstallation Clearances Installation ChecklistHigh Elevation Combustible Mantel ClearancesNon-combustible Hearth Extension GAS Connection Draft Hood Connection Combustion Ventilation AIRVenting GAS Pressure Test Aeration SystemTest for Flue Spillage Faceplate panel Faceplate and Trim Installation Door Installation Packaged Separately LOG InstallationManufacturer Final CheckWiring Diagram Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Readbefore LightingMaintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances GOLD-PLATED Doors LOG ReplacementLatch Adjustment Glass ReplacementReplacing fan FAN MaintenanceMain Assembly Parts ListBurner & Logs Description Faceplate & TrimConditions WarrantyInstaller Please complete the following information