INSTALLATION
MATERIALS REQUIRED
CLEARANCES
No electrical power supply is required for the gas control to operate. A 120 Volt AC power cord is hooked up to the fan switch and blower. Plug 3 wire cord into a suitable receptacle. Do not cut the ground terminal off under any circumstances.
When connected with 120 volts, the appliance must be electrically grounded in accordance with local codes, with a current version of CSA C22.1 (in Canada) or in the absence of local codes, with the National Electrical Code ANSI/ NFPA
Note: This unit is equipped with a heat sen- sor thermodiscwhichwillpreventthe blower from operating until the unit reaches the correct temperature.
INSTALLATION
CHECKLIST
The Regency Gas Insert is installed as listed below.
1) | Unit Location - check Clearances to Com- |
| bustibles. |
2) | Make the gas connections and electrical |
| connection for fan and vent spill switch. |
3) | Install the fl ue or liner to the sliding draft |
| hood. |
4) | Install Venting. Slide the unit into the fi re- |
| place and level. Attach draft hood to the |
| insert. |
5) | Test gas pressure. Check aeration. |
6) | Test for fl ue spillage. |
7) | Assemble and install the faceplate and |
| trim. |
8) | Install the log set. |
Minimum Fireplace Clearances
The minimum fi replace clearances for the Regency gas fi replace insert are shown in the following diagrams:
Clearances to Combustibles
From Unit |
| |
Sides | A | 7.5" / 190 mm |
Ceiling | B | 35" / 890 mm |
Mantel | C(My) | 11 / 280 mm |
From Surround |
| |
Sides | D | 2" / 50 mm |
Ceiling | E | 25.5" / 650 mm |
Mantel | F | 3" / 75 mm |
Min. Alcove Width | J | 48" / 1120 mm |
Mantel Depth | G(Mx) | 7.5" / 190 mm |
Facing (Mantel Leg) |
|
|
Side* | K | 1" / 25 mm |
Top | L | 1" / 25 mm |
*Max. width of 1" at 1" from surround, calculate
B
|
| E |
|
| G |
| F |
|
C |
| I |
|
| |
A |
|
|
D | H | J |
|
9) | Install Doors. |
10) | Install Remote Control & Wall Thermostat |
11) | Explain controls to the homeowner. |
Final check: Before leaving this unit with the customer, the installer must ensure that the ap- pliance is fi ring correctly. This includes:
a)Clocking the appliance to ensure the correct fi ring rate.
b)Adjusting the primary air, if required, to ensure that the fl ame does not carbon.
c)Ensuring that the appliance is venting correctly.
depth at 45o as shown in the diagram.
Top View
Regency | 7 |