Regency Wraps U41-NG3, U41-LP3 installation manual Safety Label, Do not Remove this Label

Page 4

SAFETY LABEL

This is a copy of the label that accompanies each Regency ULTIMATE Gas Insert. We have printed a copy of the contents here for your review. The safety label is located on the right side door panel.

NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

For the State of Massachusetts, installation and repair must be done by a plumber or gasfi tter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, fl exible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli- ances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

Duplicate

Serial No. 225

DO NOT REMOVE THIS LABEL

Serial No. 225

Listed: Vented Gas Fireplace Heater

Certified: For Canada & USA

Tested to: CAN/CGA 2.17-M91,

ANSI Z21.88b-2003/CSA 2.33b-2003 Report No. 476-1042 & 476-1752 (Jan. 2000)

NATURAL GAS FIREPLACE INSERT

Model U41-NG3:

Altitude 0-2000 ft (0-610 m)

Min. Supply Pressure

5"

WC/C.E. (1.25kPa)

Manifold Pressure High 3.8"

WC/C.E. (0.94kPa)

Manifold Pressure Low

1.1"

WC/C.E. (0.27kPa)

Orifice Size

#32

DMS

 

Altitude

0-2000

ft/pi

(0-610m)

Maximum Input

38,000 Btu/h

(11.14Kwh)

Minimum Input

20,000 Btuh

(5.86Kwh)

NATURAL GAS FIREPLACE INSERT

Model U41-NG3:

 

Field Convertible for Altitude

2000-4500 ft (610-1370 m). Use Kit #610-975

(Report No. 476-1299)

 

Min. Supply Pressure

5"

WC/C.E. (1.25kPa)

Manifold Pressure High

3.8“

WC/C.E. (0.94kPa)

Manifold Pressure Low

1.1"

WC/C.E. (0.27kPa)

Orifice Size

#33

DMS

 

Altitude

2000-4500 ft/pi

(610-1370m)

Maximum Input

34,000 Btu/h

(9.96Kwh)

Minimum Input

18,000

Btu/h

(5.28kwh)

 

 

PROPANE GAS

 

Model U41-LP3:

 

0-2000 ft (0-610 m) ONLY

Min. Supply Pressure

12"

WC/C.E. (3.00kPa)

Manifold Pressure High

11"

WC/C.E. (2.74kPa)

Manifold Pressure Low

2.9"

WC/C.E. (0.72kPa)

Orifice Size

#50

DMS

 

Altitude

0-2000

ft/pi

(0-610m)

Maximum Input

38,000

Btu/h

(11.14Kwh)

Minimum Input

20,000

Btu/h

(5.86Kwh)

 

 

 

 

 

 

 

 

This appliance must be installed in accordance with local codes, if any; if not, follow current ANSI Z223.1 / CAN/CGA-B149. This vented gas fireplace heater is not for use with air filters. For

direct discharge without duct connections. NOT

FOR USE WITH SOLID FUEL. Electrical Supply 115V,1.13A, 60Hz. WARNING: This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or

solid fuels unless all original parts have been replaced

and the fireplace re-approved by the authority

having jurisdiction.

MINIMUM CLEARANCES TO

COMBUSTIBLES: FROM HEATER

Side Wall:

A

7.5"

(190mm)

Ceiling:

B

35"

(890mm)

Mantel:

C

11"

(280mm)

Mantel Width:

G

5.5"

(140mm)

Alcove Width:

K

48"

(1120mm)

Max.Alcove Depth

M

36"

(915mm)

 

 

B

 

 

G

 

 

C

 

L

H

 

 

 

A

 

J

 

 

 

K

 

M

 

 

 

NON-COMBUSTIBLE HEARTH EXTENSION

Hearth Height

Hearth Depth

(H)(L)

Option #1:

4.0" (100mm)

16" (405mm)

Option #2:

0.5" (15mm)

24" (610mm)

Hearth Width

(J) 40"(1015mm)

 

FPI Fireplace Products International Ltd.

 

Delta, B.C.

 

Made in CANADA

918-467

4

Regency U41-3 ULTIMATE Gas Fireplace Insert

Image 4
Contents U41 Gas Insert 908-727c 07/17/06Regency GAS Fireplace Insert To the NEW OwnerTable of Contents Safety Label Do not Remove this LabelRequirements MA Code CO DetectorInstallation Installation Checklist ClearancesCombustible Mantel Clearances High ElevationNon-combustible Hearth Extension Draft Hood Connection Combustion Ventilation AIR GAS ConnectionVenting Aeration System GAS Pressure TestTest for Flue Spillage Faceplate and Trim Installation Faceplate panelLOG Installation Door Installation Packaged SeparatelyFinal Check ManufacturerWiring Diagram Operating Instructions For Your Safety Readbefore Lighting Copy of the Lighting Plate InstructionsMaintenance Instructions MaintenanceNormal Operating Sounds GAS Appliances LOG Replacement Latch AdjustmentGlass Replacement GOLD-PLATED DoorsFAN Maintenance Replacing fanParts List Main AssemblyBurner & Logs Faceplate & Trim DescriptionWarranty ConditionsInstaller Please complete the following information