INSTALLATION

OPTIONAL WALL

OPTIONAL REMOTE

THERMOSTAT

CONTROL

FINAL CHECK

Before leaving this unit with the customer, the installer must ensure that the appliance is fi ring

A wall thermostat may be installed if desired. Connect the wires as per the wiring diagrams on page 13. Use table on this page to determine the maximum wire length:

Note: Preferable if the thermostat is installed on an interior wall.

Regency offers an optional programmable thermostat but any 250-750 millivolt rated non- anticipator type thermostat that is CSA, ULC or UL approved may be used.

Use the Regency Remote Control Kit approved for this unit. Use of other systems may void your warranty.

The remote control kit comes with a hand held transmitter, a receiver and a wall mounting plate.

1)Choose a convenient location on the wall to install the receiver and the receptacle box (protection from extreme heat is very important). Run wires from the fi replace to that location, use Thermostat Wire Table.

correctly. This includes:

1)Clocking the appliance to ensure the cor- rect fi ring rate (rate noted on label) at 15 minutes.

2)Ifrequired,adjustingtheprimaryairtoensure that the fl ame does not carbon. First allow the unit to burn for 15 min. to stabilize.

CAUTION

Any alteration to the product that causes sooting or carboning that results in damage to the exterior facia is not the responsibility

CAUTION

Do not connect the millivolt

wall thermostat wires

to the 120V wires.

2)Connect the wires as per the wiring diagram above.

CAUTION

Do not connect the millivolt re-

mote control wires to

the 120V wires.

3)Install 3AAAalkaline batteries in transmitter and 4 AA alkaline batteries in the receiver. Install the receiver and its cover in the wall. Switch the remote receiver to "remote" mode. The remote control is now ready for operation.

Thermostat Wire Table

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size

Max. Length

14 GA.

50

Ft.

16 GA.

32

Ft.

18 GA.

20

Ft.

20 GA.

12

Ft.

22 GA.

9

Ft.

of the manufacturer.

3)Ensuring that the appliance is venting cor- rectly. See page 8.

Regency U41-3 ULTIMATE Gas Fireplace Insert

13

Image 13
Contents 908-727c 07/17/06 U41 Gas InsertTo the NEW Owner Regency GAS Fireplace InsertTable of Contents Do not Remove this Label Safety LabelMA Code CO Detector RequirementsInstallation Clearances Installation ChecklistCombustible Mantel Clearances High ElevationNon-combustible Hearth Extension Draft Hood Connection Combustion Ventilation AIR GAS ConnectionVenting Aeration System GAS Pressure Test Test for Flue Spillage Faceplate panel Faceplate and Trim InstallationDoor Installation Packaged Separately LOG InstallationManufacturer Final CheckWiring Diagram Operating Instructions Copy of the Lighting Plate Instructions For Your Safety Readbefore LightingMaintenance Instructions MaintenanceNormal Operating Sounds GAS Appliances Latch Adjustment LOG ReplacementGlass Replacement GOLD-PLATED DoorsReplacing fan FAN MaintenanceMain Assembly Parts ListBurner & Logs Description Faceplate & TrimConditions WarrantyInstaller Please complete the following information