Regency Wraps U41-NG3, U41-LP3 LOG Installation, Door Installation Packaged Separately

Page 12

INSTALLATION

LOG INSTALLATION

3) Close the door. The latch plate must be

centered around the alignment pin. See

diagram 2. If the latch plate interferes with

WARNING: Dangerous operating condi- tions may occur if these logs are not po- sitioned in their approved locations. Read the instructions below carefully and refer to the diagrams. If logs are broken do not use the unit until they are replaced. Broken logs can interfere with the pilot and burner operation.

The gas log kit contains the following:

a)Front Right Log - Part # 902-245

b)Front Left Log - Part # 902-244

c)Rear log - Part # 902-246

d)Embers - Part # 902-151 (2 bags)

e)Lava - Part # 902-154 (1 bag)

(Part # 653-930 for the set of three logs)

1)Remove the logs from the box and carefully unwrap them. The logs are fragile, handle with care - DO NOT FORCE into position.

2)Place the rear log, carefully sliding it down onto the pins, with the fl at side of the log facing the back of the unit. See diagram 1.

Diagram 1

Note: Do not force logs down.

3)Place the left front log, carefully sliding it down onto the left pins of the front burner. See diagram 2.

4)Place the right front log, carefully sliding it down onto the right pins of the front burner. See diagram 3.

5)Distribute the embers along the front burner but do not cover the burner ports and around the logs. Place the large embers on the fl oor of the fi rebox. Place the lava on the burner tray in front of the left and right front logs. See diagram 4.

Diagram 3

Diagram 4

DOOR INSTALLATION (Packaged Separately)

1)Open the two side doors.

2)Slide the door onto the two hinge pins mak- ing sure the two pieces are fl ush together. See diagram 1.

the corner of the stove you may want to

angle the plate slightly so the door closes

more easily.

Diagram 2

4)The latches should already be at the proper setting. If they are too hard or too easy to close, you may want to adjust them by turning the latch. See diagram 3.

5)Remove the blue plastic protective coat- ing.

6)Test the seal around the door by placing a piece of paper between the unit and the door, close the door and try to pull the paper out. If it slips out easily, then the door is not properly sealed. Turn the adjustable catch to tighten or loosen the latch. See diagram 3.

Diagram 3

Note: The door latch may require adjust- ment as the door gasket material compresses after a few fires and after glass replacement. Turn the latch to tighten or loosen the latch.

Diagram 2

Diagram 1

12

Regency U41-3 ULTIMATE Gas Fireplace Insert

Image 12
Contents U41 Gas Insert 908-727c 07/17/06Regency GAS Fireplace Insert To the NEW OwnerTable of Contents Safety Label Do not Remove this LabelRequirements MA Code CO DetectorInstallation Installation Checklist ClearancesHigh Elevation Combustible Mantel ClearancesNon-combustible Hearth Extension GAS Connection Draft Hood Connection Combustion Ventilation AIRVenting GAS Pressure Test Aeration SystemTest for Flue Spillage Faceplate and Trim Installation Faceplate panelLOG Installation Door Installation Packaged SeparatelyFinal Check ManufacturerWiring Diagram Operating Instructions For Your Safety Readbefore Lighting Copy of the Lighting Plate InstructionsMaintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances LOG Replacement Latch AdjustmentGlass Replacement GOLD-PLATED DoorsFAN Maintenance Replacing fanParts List Main AssemblyBurner & Logs Faceplate & Trim DescriptionWarranty ConditionsInstaller Please complete the following information