Regency Wraps U41-NG3, U41-LP3 LOG Replacement, GOLD-PLATED Doors, Door Gasket Glass Gasket

Page 18

MAINTENANCE

LOG REPLACEMENT

The unit should never be used with broken logs. Turn off the gas valve and allow the unit to cool before opening door to carefully remove the logs. The pilot light generates enough heat to burn someone. If for any reason a log should need replacement, you must use the proper replacement log. The position of these logs must be as shown in the diagram under Log Installation.

NOTE: Improper positioning of logs may create carbon build-up and will alter the unit’s performance which is not covered under warranty.

GOLD-PLATED DOORS

The 24 carat gold plated fi nish on the door requires little maintenance, and need only be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the war- ranty. Clean any fi ngerprints off before turning the unit on. If gasket seal is not tight - door may discolour.

DOOR GASKET AND

GLASS GASKET

If the door gasket requires replacement use 7/8" diameter oval door gasket (Part # 650-920). The glass requires 5/8" fl at glass gasket (Part # 936- 243). See your Regency Dealer.

LATCH ADJUSTMENT

The door latch may require adjustment as the doorgasketmaterialcompressesafterafewfires and after glass replace-

ment. Turn the adjust-

able latch to tighten or loosen the latch.

GLASS

REPLACEMENT

Your Regency stove is supplied with high tem- perature, 5 mm Neoceram ceramic glass that will withstand the highest heat that your unit will produce. In the event that you break your glass by impact, purchase your replacement from an authorized Regency dealer only, and follow our step-by-step instructions for replacement.

MITRED DOOR

Removing Glass

Note: Wearinggloveswillprotectyourhands while handling glass.

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the 24 nuts holding the glass retainers in place. Do not remove the nuts underneath the retainers.

4)Remove the door catch plate.

5)Remove glass retainers on sides first (3 each side) then remove two center retainers.

Note: Center glass retainers are glued to center glass.

6)Removeglassfromextrusions.Whenremov- ing center glass, leave white insulation in place.

Installing Glass

1)Install both center and side glass onto extru- sions as per diagram.

2)Place glass assembly into door frame.

3)Install retainers by placing 1 drop of glue where previously glued and put in place.

4)Install side retainers.

5)Install door catch plate.

6)Install the 24 nuts loosely, do not tighten yet.

7)Tighten side panels nuts using the following procedure:

a. tighten top & bottom outside corner nuts (2)

b.tighten inside nuts (3)

c.tighten top & bottom inside

corners (2)

8)Tighten the 10 nuts on center glass re- tainer.

9)Repeat step 7 for other side panel.

10)Replace new gasket by gluing it in place.

11)Install door onto stove and check the seal.

PANEL DOOR

1)Remove the door from the unit and place on a soft surface to prevent scratching.

2)Pull out the door gasket.

3)Remove the nuts holding the glass retainers in place.

4)Remove the glass retainers (sides, top and bottom) and the door catch plate.

5)Replace the glass. The glass must have gasketing around it.

6)Reverse the previous steps, replace the retainers and fasten with the nuts but do not overtighten, as this can break the glass. Note: the door catch plate fi ts on top of the left side retainer.

7)Put gasket glue on the retainers, but do not put glue on the screws. Replace the door gasket, the two ends butt tight together on the bottom edge of the door.

8)Replace door on the stove and check the seal.

18

Regency U41-3 ULTIMATE Gas Fireplace Insert

Image 18
Contents U41 Gas Insert 908-727c 07/17/06Regency GAS Fireplace Insert To the NEW OwnerTable of Contents Safety Label Do not Remove this LabelRequirements MA Code CO DetectorInstallation Installation Checklist ClearancesHigh Elevation Combustible Mantel ClearancesNon-combustible Hearth Extension GAS Connection Draft Hood Connection Combustion Ventilation AIRVenting GAS Pressure Test Aeration SystemTest for Flue Spillage Faceplate and Trim Installation Faceplate panelLOG Installation Door Installation Packaged SeparatelyFinal Check ManufacturerWiring Diagram Operating Instructions For Your Safety Readbefore Lighting Copy of the Lighting Plate InstructionsMaintenance Maintenance InstructionsNormal Operating Sounds GAS Appliances Glass Replacement LOG ReplacementLatch Adjustment GOLD-PLATED DoorsFAN Maintenance Replacing fanParts List Main AssemblyBurner & Logs Faceplate & Trim DescriptionWarranty ConditionsInstaller Please complete the following information