Napoleon Fireplaces GD82NT-T, GD82PT-T manual Installation Operation Instructions

Page 1

INSTALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER1 .

INSTALLATIONAND

OPERATION INSTRUCTIONS

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.33, ANSI Z21.88 FOR VENTED GAS FIREPLACE HEATERS.

GD82NT-T

NATURAL GAS

GD82PT-T

PROPANE

CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.

SAFETY INFORMATION

WARNING: If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

- WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

- Installation and service must be performed by a qualified installer, service agency or the supplier.

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212fax(705)722-6031

www.napoleonfireplaces.com • ask@napoleon.on.ca

W415-0583 / B / 05.23.07

$10.00

W415-0583 / B / 05.23.07

Image 1 Contents
Installation Operation Instructions Table of Contents Napoleon GAS Fireplace PRESIDENT’S Lifetime Limited Warranty General Information General InstructionsCare of Glass VentingVenting Lengths & AIR Terminal Locations Definitions TOP Exit / Horizontal TerminationElbow Vent Length Values VT = 4.2 x 6 = 25.2 ft HT + VT= 10.7 + 6 =16.7Since both formulas are met, this vent confi guration is ac CeptableTOP Vertical Termination TOP Exit Vertical TerminationW415-0583 / B Vertical Installation Horizontal Installation Installation Wall and Ceiling ProtectionHorizontal AIR Terminal Installation Using Flexible Vent ComponentsVertical AIR Terminal Installation Vertical Venting Installation Using Rigid Vent ComponentsExtended Horizontal AIR Terminal Installation Fireplace Vent ConnectionMobile Home Installation GAS InstallationRestricting Vertical Vents Clearance to Combustibles FramingElectrical Schematic Hard Wiring ConnectionElectrical Connection Mantle ClearancesFinishing / Servicing Burner Base Removal Blower ReplacementRemove the optional front. Instructions on Pg Battery ReplacementOperation / Maintenance Night Lighttm ReplacementTime OUT Fireplace OperationFlame Height Hand Held Remote OperationsAddress Setting Procedure DIP Switch Number 0 = on / 1 = OFF What to do if YOU Smell GAS Operating InstructionsLighting Instructions To Turn OFF GASMaintenance AdjustmentsPilot Burner Adjustment Venturi AdjustmentConversion KIT Replacements 000 Symptom Problem Test Solution Trouble Shooting GuideStanding Main Pilot goes out while Gas piping is undersizedBurner is in ‘OFF’ Supply working pressure Position Fireplace Service History W415-0583 / B